Toshiba FT-8006A Service Manual page 27

Hide thumbs Also See for FT-8006A:
Table of Contents

Advertisement

Transmitter
RF Power (50 Ω Load)
Modulation Sensitivity
Frequency Response
Frequency Tolerance (25 °C)
Code Deviation
Distortion
Adjacent CH Power
(Input 130 mV, 50 KHz Offset, 25 KHz BW)
S/N Ratio
(CCITT Filter ON, Compander ON)
Power Consumption
Base Unit
a. Standby Charge Off
b. Standby Charge ON
c. Talk
Charge Current (at CHG CONTACT)
Portable Unit
a. Stand-by
b. Talk
Battery Low Detect Voltage
Battery:
Memory:
Operating Temperature:
Storage Temperature:
Requirements Compliance
Unit is designed to fully meet with UL1459 and FCC Rules, Part 15 and 68.
0.3 kHz
3.0 kHz
(+)
(−)
Ni-Cd Battery 600 mAH (@1.2 V × 3 = 3.6)
10 Memories (16 Digits) + 1 Redial Memory (32 Digits)
−10 °C ~ 50°C
−20 °C ~ 60°C
a &a
Unit
Nominal
−7
dBm
mV
10.5
−1
dB
−1.5
dB
Hz
0
kHz
8
%
1
dB
55
dB
55
dB
40
mA
70
mA
165
mA
110
mA
90
mA
3.4
mA
85
V
3.3
Limit
−10 ~ −4
7 ~ 15
−5 ~ +3
−5.5 ~ +2.5
±1500
< 11
< 5
> 50
> 50
> 35
< 90
150 ~ 190
< 130
80 ~ 100
< 4
< 100
3.0 ~ 3.6