Iecex Nameplate - Ametek DR6300 SERIES Supplementary Instructions Manual

Non-contact level
Hide thumbs Also See for DR6300 SERIES:
Table of Contents

Advertisement

DR6300 SERIES

1.5 IECEx nameplate

Figure 1-1: Ex ia / Ex iaD nameplate (4...20 mA output)
Figure 1-2: Ex d[ia] / Ex tD[iaD] nameplate (4...20 mA output)
1 IECEx certification agency code
2 Types of device protection for explosive atmospheres with gas, including approved Gas Groups (IIA, IIB or IIC) and tem-
perature classes (T6...T4 or T3 - depends on the antenna type) and equipment protection level
3 Types of device protection for explosive atmospheres with dust, zones, degree of ingress protection (if fitted with the
appropriate cable glands) and maximum surface temperature
4 Intrinsically-safe circuit data
5 Maximum voltage in accordance with IEC 60079-0
6 Minimum waiting time after power-off before it is safe to open the terminal compartment
7 Cable entry type and size (Aluminium housing: M26×1.5, M20×1.5, ½ NPT or G ½; Stainless steel housing: M25×1.5,
M20×1.5, ½ NPT or G ½)
DR6300-LM IECEx, EDO 2-13-118, Issue 1
GENERAL SAFETY INFORMATION
www.drexelbrook.com