Maximum Surface Temperature Of The Housing; Process Pressure - Ametek DR6300 SERIES Supplementary Instructions Manual

Non-contact level
Hide thumbs Also See for DR6300 SERIES:
Table of Contents

Advertisement

INSTALLATION
2

2.2.2 Maximum surface temperature of the housing

Zone 20: Ex iaD devices only
Zone 20/21: Ex iaD and Ex tD[iaD] devices only
Max. ambient temperature
Drop and horn antennas
[°C]
[°F]
+60
+140
+75
+167
+85
+185
+59
+138
-
1 Max. flange temperature is +100°C / +212°F, if the PP Drop antenna is used. Max. flange temperature is +150°C / +302°F, if the PTFE
Drop antenna is used.
2 Do not use the PP Drop antenna. Max. flange temperature is +150°C / +302°F, if the PTFE Drop antenna is used.

2.2.3 Process pressure

Equipment protection level
EPL Ga or Ga/Gb
Others
1 Atmospheric pressure
11
Drop and horn antennas
with the distance piece
[°C]
[°F]
+60
+75
+85
+62
-
+57
Max. flange temperature
[°C]
+140
+60
+167
+75
+185
+85
+143
+150
1
+134
+200
2
Allowable process pressure
[kPa]
80...110
As per non-Ex device
www.drexelbrook.com
DR6300 SERIES
Max. surface
temperature
[°F]
[°C]
+140
+62
+167
+77
+185
+87
≤+90
+302
1
≤+90
+302
2
[psi]
1
As per non-Ex device
DR6300-LM IECEx, EDO 2-13-118, Issue 1
[°F]
+143
+170
+188
≤+194
≤+194
11.6...16
1