4. TROUBLE SHOOTING
For testing, Max power output is needed.
Check TP1 Over 21dBm?
Check TP2 Over 21dBm?
Check TP Over 21dBm?
Check TP4 Over 7dBm?
RTR6285 Maximun output Power = 7dBm
RTR6285 minimun output Power = -80dBm
LGE Internal Use Only
Check ANT_SEL 0, 1, 2
(High, Low, Low)
No
No
No
No
Check PAM Block
Refer to 1.5.4
Yes
RF Tx Level is OK
Yes
Check TX Module
Yes
Check Duplexer
Yes
Check RTR6285
- 88 -
Copyright © 2010 LG Electronics. Inc. All right reserved.