LG MG180C Service Manual page 34

Table of Contents

Advertisement

3.5.8. Charging
Charging block in ABB processes charging operation by using VBAT, ICHG value through ADC
channel. Battery Block Indication and SPEC of MG180c is as follow.
4.2V~3.88V
1. Charging method: CC-CV
2. Charger detect voltage: about 5.2V
3. Charging time: 2h 30 min under
4. Icon stop current: 120mA
5. Charging current: 550mA
6. CV voltage: 4.2V
7. Cutoff current: 30mA
8. Full charge indication current (icon stop current) : 100mA
9. Recharge voltage: 4.16V
10. Low battery alarm
a. Idle: 3.55V
b. Dedicated: 3.59V
11. Low battery alarm interval :
a. Idle: 2min
b. Dedicated:1min
12. Power-off voltage without TA : 3.35V
Power-off voltage with TA : 2.80V
13. Charging temperature ADC range
a. ~ -5°C : small charging operation.
b. -5°C ~ 50°C : charging.
c. 50°C ~ : small charging operation.
3.87V~3.75V
Figure 15. Battery Block Indication
- 33 -
3. H/W Circuit Description
3.74V~3.68V
3.67V~3.60V

Advertisement

Table of Contents
loading

Table of Contents