Operation - Greenlee EHP700L Instruction Manual

Battery-powered pump
Table of Contents

Advertisement

Operation (cont'd)
Charging the Battery
Read the instructions supplied with the battery charger.
LED Indicator (red)
This tool is equipped with a special circuit board incor-
porating several important features to inform the user
about the current status of the unit. The LED signals in
the following cases:
What happens
Flashing light for 2 seconds
Constant light for 20 seconds
at end of cycle
Tool will not start, and
constant light for 20 seconds
when trigger is released
Tool will stop, and constant
light for 20 seconds after
trigger is released
Tool will stop, and flashing
light for 20 seconds when
trigger is released
Flashing light and audible
alert for 3 seconds after cycle
Flashing light and audible
alert for 1 second after cycle
Greenlee / A Textron Company
Signal
What it means
Battery is inserted in tool.
Battery charge is below
17 V at beginning of cycle.
Battery charge is below
16 V at beginning of cycle.
Battery voltage drops
below 13 V during cycle.
Motor current exceeds
20 A during cycle.
Circuit has become too hot.
Serious error—Crimping
pressure has not been
reached while motor was
running.
Error—Required crimping
pressure has not been
reached. Operator has
interrupted crimping cycle
manually while motor was
not running.
EHP700L Battery-powered Pump
Operating Procedure
1. Connect the male coupling of the hydraulic hose to
the female coupling of the pump.
2. Select the correct working unit for the intended
application.
3. Connect the tool head to the pump via the hydraulic
hose.
• Do not operate the pump without a working unit.
• Before operating the pump, check the oil level and
adjust if necessary.
Failure to observe these precautions may result in
injury or property damage.
4. Connect the pendant switch, which the pump
recognizes through a special coding. The built-in
trigger will be deactivated accordingly.
5. Plug the battery (and spare battery, if using) into the
socket.
6. The pump is now ready to operate, and the LCD
display is activated.
7. Select the program for the intended application by
turning the selection knob or the data function.
8. Initiate the working cycle by activating the advance
function of the forward and return switch.
Note: The retraction button of the forward and return
switch is always active and can be actuated at any time
and in any program.
9
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070

Advertisement

Table of Contents
loading

Table of Contents