6.4 Readout menu

The readout menu can be used to call up a number of current
sensor values to obtain more information on the appliance's
performance. Modifying values or settings is not possible in
this menu. The readout menu is displayed as follows:
1. In operating mode, press the ' Menu ' key. Now the display
shows the settings menu.
operating mode
settings menu
2. Use the '+' and '-' keys to go to the readout menu.
readout menu
Step no. readout value
01
02
03
04
09
18
Description readout value
Current temperature from dwelling
Current temperature outdoor sensor
Bypass status (ON = bypass function active, OFF = bypass function not active)
Status frost protection (ON = frost protection active, OFF = frost protection not active)
Current relative humidity (plus version)
Renovent Excellent 180
3. Activate the readout menu.
4
Use the '+' and the '-' key to scroll through the readout
menu'.
5
Press the 'R' key twice to go to operating mode.
If no key is operated during 5 minutes, the appliance auto-
matically returns to operating mode.
operating mode
Display layout
readout value
Step no. readout value;
refer to the table below
for an explanation