Exploded View Appliance - Brink Renovent Excellent 180 Installation Instructions Manual

Hide thumbs Also See for Renovent Excellent 180:
Table of Contents

Advertisement

Available languages

Available languages

Chapter 3

3.3 Exploded view appliance

10
9
8
7
1 Indoor temperature sensor
2
3 Heat exchanger
4
5 Outdoor temperature sensor
6 Condensate discharge
7 Exhaust fan
8 Control board
9 Display and 4 control buttons
10 Supply fan
11 Mains cable 230 V
12 eBus connection
13 Modular connector multiple switch
14 Service connector
15 Connector 9-pole
16 Extra gland
17 Extra gland
8
1
2
3
4
5
6
Measures the dwelling exhaust air temperature
Ensures heat transfer between supply and exhaust air
Filters outdoor air supplied to the dwelling
Measures outside air temperature.
Connection condensate discharge
Discharges air from the dwelling to the atmosphere.
Contains the control electronics for the functions.
Interface between user and control electronics.
Feeds fresh air into the dwelling.
Gland power cable 230 V
Two-pole screw connector for eBus connection
Computer connection for service purposes.
Contains the various control inputs and outputs; only for Plus version
For instance for cable to RH (humidity) sensor
For instance for 230 V cable to preheater or postheater; only for Plus version
Renovent Excellent 180
Version
16 17
11 12
13 14 15
Connections top appliance

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Renovent excellent 180 plus

Table of Contents