Trouble Shooting - Midea MFM-24ARN1-Q Service Manual

Air conditioner floor standing type
Hide thumbs Also See for MFM-24ARN1-Q:
Table of Contents

Advertisement

DM16-01.01.25en

10.Trouble shooting

10.1 Self-diagnosis
10.1.1 LEDs for the indication of indoor trouble
For 24K
Codes
Contents
P4
Temperature protection of indoor evaporator
P5
Temperature protection of outdoor condenser
P9
Anti-cold air(For heat pump models)
E1
Open- or short-circuit of T1 temperature sensor
E2
Open- or short-circuit of T2 temperature sensor
E3
Open- or short-circuit of T3 temperature sensor
E6
Protection of outdoor unit
EC
Refrigerant leakage detection
HS
Defrosting(For heat pump models)
For other models:
Codes
Contents
P4
Temperature protection of indoor evaporator
P5
Temperature protection of outdoor condenser
P7
Temperature protection of compressor discharge
P9
Anti-cold wind(For heat pump models)
P10
Low pressure protection
P11
High pressure protection
P12
Current overload protection
E1
Open- or short-circuit of T1 temperature sensor
E2
Open- or short-circuit of T2 temperature sensor
E3
Open- or short-circuit of T3 temperature sensor
E4
Open- or short-circuit of T4 temperature sensor
E5
Communication malfunction between indoor unit and outdoor unit
E10
Low pressure failure of compressor
E13
Lack of phase
E14
Default phase of compressor
EC
Refrigerant leakage detection
HS
Defrosting(For heat pump models)
43
Floor Standing MFM
Service manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents