LOCATION 19 - DEVICE OPTIONS (8 segments, feature selection data)
Location 19 is used to enable various system features of the NX-320E power supply.
Option
1
2
3
4
5-8
NX-320E Installation manual
ON
AC report always
sent
OFF
Follows control
panel
ON
Enables periodic battery test.
Enables battery missing every 30 seconds.
ON
Enables low battery test.
If enabled, the NX-320E will report low battery to the central station.
ON
Enables siren tamper/trouble reporting.
If enabled, the NX-320E will report a siren tamper to the central station.
Reserved
Page 15
Function
If enabled, an AC Fail report will be sent if power is lost
for the time programmed in location 18. If "off", the
report will only be sent if the control panel has not sent
an AC power lost report, and AC fail report is enabled in
location 37 of the control panel.