Emptying And Cleaning Tanks - Chariot CS20 Operating Instructions Manual

Iscrub 20
Table of Contents

Advertisement

Emptying and Cleaning Tanks

1. Park the machine next to a floor drain. Drain hoses
are at the rear of the machine.
2. Turn the machine power off.
Recovery Tank
1. Pull the recovery drain hose from the mounting
pocket. Lift cap, pinch hose then lower hose in
direction of the drain. Do not stand in front of end of
hose. Recovered solution will come out with force.
2. To flush the recovery tank, lift the control console to
access the recovery tank. Do not use water hotter
than 140°F (60°C) to clean tank. Damage may
occur.
3. Clean debris from sight dome and cover surface.
4. Clean off the float shut-off screen and inspect for
free movement of float.
5. Replace the drain cap and secure drain hose.
6. If machine is to be stored, tilt the recovery tank
back and prop the console up, partially opening
each.
Solution Tank
1. Pull the solution drain hose from its mounting
2. Open the control console.
3. Flush the solution tank out with clean water and
NOTE: Never allow solution to remain in tank.
Damage to tank, seals and valves could occur.
RECOVERY
DRAIN HOSE
STORAGE POSITION
86333220 CS20
pocket. Lower hose in direction of drain.
run several gallons of clean water through sys-
tems. Do not use water hotter than 140°F (60°C) to
clean tank. Damage may occur.
Operations
SOLUTION
DRAIN HOSE
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Csc20Cs22spCsc22spCsx20

Table of Contents