Download Print this page

Troubleshooting - ikitchening PFE-600 Manual

Electric pressure fryer(with pump)

Advertisement

temperature is up to 250℃, temperature limiter can cut off the heating power to make sure of the safe. Operator
should check the reason for overheat and try to get rid of it. If needed, you should press the reset key in the
"temperature limiter" to restart the machine.

TROUBLESHOOTING

No problem
1
Machine not work
2
Not Heating
3
Heating slowly
4
Not
controlling
temperature
automatically
5
Not timing
6
Operating pressure
too high
7
Pressure does not
build or too low
www.ikitchening.com
Cause
Check the electric power on or off,
see the fuse whether burn, miss
phase or neutral wire not install well.
contactor failure, or the wire loose
Time relay failure
Panel
not
work
well
temperature sensor failure
Weak or burnt out element
Elements not meet well
Temperature sensor failure
Circle not contacting well
Circle not contacting well
Time Controller not work
Deadweight clogged
Exhaust line to stack clogged
Pressure gauge failure
Solenoid valve leaking or not closing
Lid gasket leaking
Lid open or not latched
Product not fresh or not enough
product in fryer
Metal shipping spacer not removed
from deadweight
PFE-600 Electric Pressure Fryer(with pump)
PFE-600 Electric Pressure Fryer(with pump)
correction
Reinstall the wire
Reinstall the contactor or have
wires tightened
Adjust it or reset it
or
the
Adjust it or reset them
Reset the element(checked by
multi-meter)
Adjust the wire's contact
Mend it or reset it
Adjust the wire's contact
Adjust the wire's contact
Reset the controller
Turn unit off and allow fryer
to cool to release pressure
from
frypot;
deadweight and clean ,per
cleaning the deadweight valve
section
Clean Exhaust line to stack
Reset it, don't mend it
Have solenoid valve checked
or cleaned
Reverse gasket or lid needs
adjusted
Close and latch lid
Place proper quantity of fresh
product
within
generate steam
Remove shipping spacer
remove
frypot
to
5 of 5

Advertisement

loading