Maintenance; Specifications - Ozone Solutions OX-12 Installation And Operation Manual

12-scfh oxygen generator (concentrator)
Table of Contents

Advertisement

OX-12 Oxygen Generator Manual

Maintenance

Compressors require a rebuild after 5,000 to 12,000-hours of operation, depending on
environmental conditions.
See the Service Parts section for information on compressor rebuild kits and inlet filters.

Specifications

Compressed Air
Pressure Relief Valve setting: 35-psig ±10%
Oxygen Output
12-SCFH (5.5-SLPM) at 90% +3%/-5% oxygen by volume at 9-psig minimum (at lab
conditions, derated performance at higher temperature and humidity) 1/8" NPT Female
Pipe connection
Electrical Input
120 VAC, single phase, 60 Hz, 4.0 Amps, 425 Watts
220 VAC, single phase, 50 Hz, 2.0 Amps, 425 Watts
220 VAC, single phase, 60 Hz, 2.0 Amps, 425 Watts