Introduction; Installation - Ozone Solutions OX-12 Installation And Operation Manual

12-scfh oxygen generator (concentrator)
Table of Contents

Advertisement

OX-12 Oxygen Generator Manual

Introduction

The operation of the Oxygen Generator is based on the pressure swing adsorption
(PSA) cycle using synthetic zeolite molecular sieve. The Oxygen Generator is capable
of delivering oxygen flows up to 12-standard cubic feet per hour (SCFH) at over 90% by
volume oxygen concentration. The main components of the Oxygen Generator are an
Oxygen Concentrator Module and an oil less air compressor.
Typical applications for the Oxygen Generator include aquaculture and feed gas for
ozone generation. Ozone Solutions can supply oxygen generators, sub-systems and
components for generators in many capacities.

Installation

Place the unit in a manner that allows for sufficient access space around the Oxygen
Generator to perform normal maintenance and service. Also ensure there will be a free
flow of cooling air around the unit. Connect the unit to a grounded power source rated
for the voltage and current requirements stated on the label on the unit.
IMPORTANT: The location of the Oxygen Generator must be well ventilated. Contact
Ozone Solutions if further assistance is needed.
IMPORTANT: Choose a location for the Oxygen Generator that does not allow rain or
condensation to contact the unit. The Oxygen Generator is not weather proof. It must
be operated indoors or in an enclosure in a noncondensing environment.