  • Page 1 451 Black Forest Road Hull, IA 51239 Ph: (712) 439-6880 Fax: (712) 439-6733 www.ozonesolutions.com OX-12 12-SCFH Oxygen Generator (Concentrator) Installation and Operation Manual...
  • Page 2: Cautions, Warnings And Hazards

    OX-12 Oxygen Generator Manual Cautions, Warnings and Hazards Oxygen is a powerful oxidizing agent; it can cause fire or explosion. Observe strict cleanliness procedures when fabricating and connecting the oxygen piping. It is imperative that oxygen systems be properly cleaned and inspected to insure that no combustible materials remain in the connecting piping and fittings.
  • Page 3: Table Of Contents

    Page Cautions, Warnings and Hazards ..............2 Introduction ....................4 Installation ....................4 Operation ..................... 5 Maintenance ....................6 Specifications ....................6 Mechanical Outline Drawing ................. 7 Service Parts ....................8 How to Contact Ozone Solutions ..............8 Page 3...
  • Page 4: Introduction

    The main components of the Oxygen Generator are an Oxygen Concentrator Module and an oil less air compressor. Typical applications for the Oxygen Generator include aquaculture and feed gas for ozone generation. Ozone Solutions can supply oxygen generators, sub-systems and components for generators in many capacities. Installation Place the unit in a manner that allows for sufficient access space around the Oxygen Generator to perform normal maintenance and service.
  • Page 5: Operation

    (using psig):  14 7     oxygenpressure  adjustedflow measuredflow x 14 7 Please contact Ozone Solutions if additional assistance is required. Do not allow the oxygen product to vent freely. Do not exceed rated capacity. Page 5...
  • Page 6: Maintenance

    OX-12 Oxygen Generator Manual Maintenance Compressors require a rebuild after 5,000 to 12,000-hours of operation, depending on environmental conditions. See the Service Parts section for information on compressor rebuild kits and inlet filters. Specifications Compressed Air Pressure Relief Valve setting: 35-psig ±10% Oxygen Output 12-SCFH (5.5-SLPM) at 90% +3%/-5% oxygen by volume at 9-psig minimum (at lab...
  • Page 7: Mechanical Outline Drawing

    OX-12 Oxygen Generator Manual Environment The Oxygen Generator is not weather proof; it must be operated indoors or in an enclosure in a noncondensing environment. If the space is occupied, sufficient ventilation must be provided to prevent the accumulation of low oxygen concentration waste gas in the space.
  • Page 8: Service Parts

    OX-12 Oxygen Generator Manual Service Parts Service parts listed below can be obtained directly from Ozone Solutions. Hose can generally be obtained locally; specifications are listed below. Always replace hoses with equal or better specifications. Other parts are not considered regular service items.