Coleman 60130 User Manual page 9

For 6 / 12 volt lead-acid batteries plus battery maintainer & rejuvenator
Table of Contents

Advertisement

• Bulk Charge:
Charges using a constant maximum current (1A) until the battery reaches 7.2V(6 Volt
Batteries)/14.4V (12 Volt Batteries) - (LED Color - Yellow)
• Fully / Float:
Battery is fully charged and is being maintained. (LED Color - GREEN)
STEP 4 - Disconnecting the Battery charger from Battery
• If the Battery is out of the vehicle.
o Switch OFF and Remove the AC Power Socket from the outlet.
o Remove the Black lead and then the Red lead.
o Check electrolyte levels if possible.
(As they may need topping up with distilled water after charging)
LED STATUS INIDICATOR TABLE:
A.C. Power connected, battery disconnected
Bulk Charging
Level 1 Charging
Level 2,3 Charging
Battery Reverse polarity connection
A.C. Power OFF
CHARGING CURVE (VOLTAGE):
Power
Charging
(Red)
(Yellow)
ON
OFF
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
OFF
Full
Fault
(Green)
(Red)
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
9