WARNING - RISK OF EXPLOSIVE GASES WHEN WORKING IN VICINITY OF A LEAD- ACID BATTERY. DANGEROUS. EXPLOSIVE GASES DEVELOP DURING NORMAL BATTERY OPERATION. IT IS IMPORTANT THAT EACH TIME BEFORE USING YOUR CHARGER, YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY. l To reduce risk of battery explosion, follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery.
l Someone should be within range of your voice or close enough to come to your aid when you work near a lead-acid battery. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing or eyes. Wear complete eye and clothing protection.
NEAR BATTERY MAY CAUSE BATTERY EXPLOSION. TO REDUCE RISK OF A SPARK NEAR BATTERY: l Position AC and DC cords to reduce risk of damage by hood, door or moving engine part. l Stay clear of fan blades, belts, pulleys, and any other parts that can cause injury to persons.
battery voltage and continue to peak performance to the battery. • Short circuit protection: The charger will automatically turn off when the output short circuit occurred and prevent any damage • Reverse polarity protection : The charger can automatically shut off when the output polarity is reversed and without damage SAFETY &...
• Operating Temperature: -10 to 45° C • Storage Temperature: -25 to 85°C • Operating Humidity Range: 0 to 90% RH • Cooling: Passive / Natural TECHNICAL SPECIFICATIONS: Part Number 60130 Type Automatic Input Voltage Range 100~120Vac Input Frequency 50/60Hz...
Page 7
• If the Battery is still in the vehicle, determine if the vehicle is positively (+) or negatively (-) earthed. o If Negatively Earthed (Most Common) – FIRST Connect the Red (+) battery charger lead to the positive (+) Battery post and then connect the Black (-) battery charger lead to the vehicle’s chassis and away from the fuel line.
o If Positively Earthed – FIRST Connect the Black (-) battery charger lead to the Negative (-) battery post and then connect the Red (+) battery charger lead to the Vehicle’s chassis and far away from the fuel line. STEP 3 - Connect the battery charger to Mains Power (120Vac) •...
Page 9
• Bulk Charge: Charges using a constant maximum current (1A) until the battery reaches 7.2V(6 Volt Batteries)/14.4V (12 Volt Batteries) - (LED Color - Yellow) • Fully / Float: Battery is fully charged and is being maintained. (LED Color - GREEN) STEP 4 - Disconnecting the Battery charger from Battery •...