Coleman 60130 User Manual
Coleman 60130 User Manual

Coleman 60130 User Manual

For 6 / 12 volt lead-acid batteries plus battery maintainer & rejuvenator

Advertisement

Quick Links

User Manual

BATTERY CHARGER

Plus Battery maintainer & Rejuvenator
BATTERY CHARGER
For 6 / 12 Volt lead-acid batteries
Model No. 60130
1

Advertisement

Table of Contents
loading

Summary of Contents for Coleman 60130

  • Page 1: User Manual

    User Manual BATTERY CHARGER Plus Battery maintainer & Rejuvenator BATTERY CHARGER For 6 / 12 Volt lead-acid batteries Model No. 60130...
  • Page 2: Personal Precautions

    WARNING - RISK OF EXPLOSIVE GASES WHEN WORKING IN VICINITY OF A LEAD- ACID BATTERY. DANGEROUS. EXPLOSIVE GASES DEVELOP DURING NORMAL BATTERY OPERATION. IT IS IMPORTANT THAT EACH TIME BEFORE USING YOUR CHARGER, YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY. l To reduce risk of battery explosion, follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery.
  • Page 3: Charger Location

    l Someone should be within range of your voice or close enough to come to your aid when you work near a lead-acid battery. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing or eyes. Wear complete eye and clothing protection.
  • Page 4: Main Features

    NEAR BATTERY MAY CAUSE BATTERY EXPLOSION. TO REDUCE RISK OF A SPARK NEAR BATTERY: l Position AC and DC cords to reduce risk of damage by hood, door or moving engine part. l Stay clear of fan blades, belts, pulleys, and any other parts that can cause injury to persons.
  • Page 5: Battery Types & Capacity

    battery voltage and continue to peak performance to the battery. • Short circuit protection: The charger will automatically turn off when the output short circuit occurred and prevent any damage • Reverse polarity protection : The charger can automatically shut off when the output polarity is reversed and without damage SAFETY &...
  • Page 6: Environmental Characteristics

    • Operating Temperature: -10 to 45° C • Storage Temperature: -25 to 85°C • Operating Humidity Range: 0 to 90% RH • Cooling: Passive / Natural TECHNICAL SPECIFICATIONS: Part Number 60130 Type Automatic Input Voltage Range 100~120Vac Input Frequency 50/60Hz...
  • Page 7 • If the Battery is still in the vehicle, determine if the vehicle is positively (+) or negatively (-) earthed. o If Negatively Earthed (Most Common) – FIRST Connect the Red (+) battery charger lead to the positive (+) Battery post and then connect the Black (-) battery charger lead to the vehicle’s chassis and away from the fuel line.
  • Page 8: The Charging Process

    o If Positively Earthed – FIRST Connect the Black (-) battery charger lead to the Negative (-) battery post and then connect the Red (+) battery charger lead to the Vehicle’s chassis and far away from the fuel line. STEP 3 - Connect the battery charger to Mains Power (120Vac) •...
  • Page 9 • Bulk Charge: Charges using a constant maximum current (1A) until the battery reaches 7.2V(6 Volt Batteries)/14.4V (12 Volt Batteries) - (LED Color - Yellow) • Fully / Float: Battery is fully charged and is being maintained. (LED Color - GREEN) STEP 4 - Disconnecting the Battery charger from Battery •...
  • Page 10: Maintenance

    To obtain more information, warranty service or technical support, please contact: Sunforce Products Inc. +1 888-478-6435 www.sunforceproducts.com info@sunforceproducts.com ® Coleman are registered trademarks of The Coleman Company, Inc., used under license. © 2016 The Coleman Company, Inc. Sunforce Products Inc. 9015 Avon #2017, Montreal West, QC, CANADA H4X2G8...

Table of Contents