Summary of Contents for DENRYO SA-MN05

  • Page 1 Solar Charge Controller SA-MN05 User's Manual Ver. 2.10E RoHS DENRYO CO., LTD.
  • Page 2: Table Of Contents

    Contents 1. Safety Information................2. Appearance..................3. Connection..................4. Operation..................5. LED Indications................6. Night Light Timer................7. Troubleshooting................8. Specifications................... 9. Certifications..................10. Glossary................... Thank you for purchasing the SolarAmp mini solar charge controller. This manual contains important safety, installation and operating instructions for the SolarAmp mini solar charge controller in order to prevent the users from any damage.
  • Page 3: Safety Information

    1. Safety Information 1-2 : Protect from direct rain 1-1 : Do NOT short circuit 1-3 : Explosion hazard 1-4 : Mounting direction  1-5 : Negative earth ground 1-6 : Do NOT reverse polarity connection − + − + +...
  • Page 4: Appearance

    2. Appearance MODE SW STATUS LED STATUS MODE SW MODE LED MODE ERROR LED ERROR SELECT SW SELECT SW RESET BATTERY LOAD + − + − + − (mm)
  • Page 5: Connection

    3. Connection 3-1 : Connect wires to 3-2 : Connect to load SolarAmp mini first Screw tightly not to loose. It is recommended to install an external fuses (5A) between controller and load. − + 3-3 : Connect to PV 3-4 : Connect to battery Cover the PV with cloth It is recommended to install...
  • Page 6: Operation

    4. Operation 4-1 : Setting Switches Push MODE SW Push SELECT SW When the SW is pushed, mode will switch as illustrated below. Confirm the set contents by checking MODE LED and STATUS LED blinking. Select Setting Mode Setting Mode Details* Select Battery Type (1) Select Battery Type...
  • Page 7 Setting Mode Details (1) Select Battery Type (2) LVD Voltage Compensation MODE LED MODE LED Sealed STATUS LED STATUS LED Flooded -0.1V STATUS LED STATUS LED -0.2V STATUS LED STATUS LED +0.1V STATUS LED STATUS LED +0.2V STATUS LED (3) Night Light ON/OFF Setting (4) Night Light Timer Setting MODE LED MODE LED...
  • Page 8 4-2 : Reset (1) Push MODE SW and SELECT SW simultaneously. (2) Release your hands from both of the SWs than LED blink twice. Successfully reset will be completed. 4-3 : Factory default (1) Push MODE SW and SELECT SW simultaneously. (2) Keep pushing MODE SW and release your hand from SELECT SW only.
  • Page 9: Led Indications

    5. LED Indications 5-1 : STATUS LED and ERROR LED during normal operation ERROR LED ERROR Descriptions STATUS LED STATUS Descriptions LVD (LOAD OFF) Battery Level Low Battery Error Middle PV Error Full LVD & PV Error 5-2 : MODE LED and STATUS LED during mode setting MODE LED MODE Description STATUS LED...
  • Page 10: Night Light Timer

    6. Night Light Timer 6-1 : Multi Timer Night Night Light OFF (Load is always ON) D/D Load ON (All night timer) Normal Timer 6h Normal Timer 8h Normal Timer 10h Normal Timer 12h Normal Timer 14h Rate Timer 40% Rate Timer 50% Rate Timer 60% Rate Timer 70%...
  • Page 11 6-2 : Early Start Lighting Function Night Dusk Turn on early Other controller's night light load ON point SolarAmp mini early start lighting load ON point SolarAmp mini has the early start lighting function. The load will start to turn on from dusk. This function will operate the following day after insatlling SolarAmp mini at the earliest.
  • Page 12 6-3 : Rate Timer Function Night Rate 80% Rate 70% Winter Rate 60% Rate 50% Rate 40% Rate 40% Rate 50% Summer Rate 60% Rate 70% Rate 80% SolarAmp mini rate timer is different from a traditional night-light timer. The lighting time of load is set by a rate (%) of night time. Even if the night time is changed seasonally, the lighting-off time will be apporoximately at the same time.
  • Page 13: Troubleshooting

    7. Troubleshooting 7-1 : Lighting ERROR LED LVD : The battery voltage is low. Please charge with the battery 12.5V or more until becoming it. Battery : The cause is as follows. • Battery is not connected • Battery is low or too high voltage •...
  • Page 14: Specifications

    8. Specifications Model SA-MN05 12 V System Voltage 25 V Max. input Voltage Max. input Current Max. load Current Min. input battery Voltage Negative ground Grounding 1 mA Self-consumption Current Fuse : 10 A Reverse Polarity Protected - 20 〜 + 60 ℃...
  • Page 15: Glossary

    This Document must not be copied, photocopied, reproduced or converted to any electronic or machine-readable form in whole or in part without prior written approval of DENRYO CO., LTD. © 2010-2012 DENRYO CO., LTD. All Rights Reserved. DENRYO CO., LTD. 28-5, Nishinippori 2 Chome, Arakawa-ku...

Table of Contents