Fault
Controls have reduced
luminosity.
Displays do not illuminate.
Appliance is not cooling,
temperature display and light
are lit.
Possible cause
When the appliance is not
used for some time,
the display on the fascia
switches to energy saving
mode.
Power failure; the fuse has
been switched off; the mains
plug has not been inserted
properly.
Showroom mode is
switched on.
Remedial action
As soon as the appliance is again used, e.g.
the door is opened, the display switches back
to normal illumination.
Connect mains plug. Check whether the power
is on, check the fuses.
Hold down temperature selection button
fig. "/1 for 10 seconds until
an acknowledgement signal sounds.
After a short time check whether your
appliance is cooling.