Download Print this page

Specifications - Mantracourt PP1 User Manual

Power pack 1 & solar panel 1
Hide thumbs Also See for PP1:

Advertisement

The PP1 and SP1 combination was designed to supply a 12 Volt system with a maximum continuous average current
consumption of 53mA. The power rating of the system would be 0.636W; if used 24 hours per day this would equate
to 15.264 Watt-hours. On an average British day, this power could be produced by a solar panel array of
approximately 6 watts. However, you do of course get more power in the middle of summer than in winter. In
summer you could produce that power required with only 3 watts of solar panels. In winter you would need 15 watts
of panels to produce enough power. Hence the SP1 20W panel is more than adequate.
The output from the PP1 is fuse protected by a 6.3 Amp anti surge fuse, this is to protect against short circuit on
the output, fuses are 6.3A 20x5mm ceramic glass tube type. The 100-240V AC input charger is fuse protected in the
13Amp plug, if this plug is replaced with any other connector please consider how your PP1 is protected.

Specifications

Electrical
Output Voltage
Internal Capacity
External Power Supply Voltage
Input Frequency
Cable Lengths
12 V Output Cable to Bare End
Solar Panel to Power Pack
Mains Charging cable *
* Supplied with 13 Amp Plug
Environmental
IP rating
Operating temperature range **
Storage temperature
Humidity
** When being charged from Mains min operating temperature 0
5
Mantracourt Electronics Limited PP1 & SP1 User Manual
Min
Typical
12
33
100
-
47
-
5
5
0.8
IP67
-20
-20
0
o
C max operating temperature if 40
Max
Units
V DC
AHr
250
Volts AC
63
Hz
m
m
m
+50
C
+50
C
95
%RH
o
C

Advertisement

loading

Related Products for Mantracourt PP1

This manual is also suitable for:

Sp1