Kasco marine 1400JFL Owner's Manual

Aerating fountain
Hide thumbs Also See for 1400JFL:

Advertisement

Quick Links

I. Safety Instructions ..........................................
II. General Owner's Instructions..............................
IV. Maintenance Recommendations..........................
V. C-25 Instructions.............................................
VI. Parts Included & Tools Needed...........................
VII. Nozzle Options & Pattern Sizes..........................
VIII. Replacement Parts & Assembly Diagram...............
X. Troubleshooting Tips.........................................
XI. Warranty Registration Information........................
www.KascoMarine.com * sales@kascomarine.com
Patent Pending
CONTENTS
2
3
4-5
6
7
8
9
10
11-12
13
14
Made in the USA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1400JFL and is the answer not in the manual?

Questions and answers

Summary of Contents for Kasco marine 1400JFL

  • Page 1: Table Of Contents

    VIII. Replacement Parts & Assembly Diagram…………… IX. Assembly & Installation Instructions………………… 11-12 X. Troubleshooting Tips………………………………….. XI. Warranty Registration Information…………………… Kasco Marine, Inc. 800 Deere Rd. Prescott, WI 54021 Phone (715) 262-4488 * Fax (715) 262-4487 www.KascoMarine.com * sales@kascomarine.com Made in the USA...
  • Page 2 We at Kasco Marine, Inc. would like to both thank and congratulate you on your purchase of the 1400JF Aerating Fountain. We appreciate you choosing Kasco and for your purchase. Your decision to purchase Kasco’s 1400JF Aerating Fountain will not disappoint you. The 1400JF Aerating Fountain will be a great addition to your body of water.
  • Page 3: General Owner's Instructions

    (See Warranty, Warranty Claim, & Return Policy on pages 4 & 5). Please fill out the enclosed, ad- dressed Warranty Card and mail it to Kasco Marine to start your warranty coverage. You may also register your Fountain online at: www.kascomarine.com/solutions_warranty_registration.htm .
  • Page 4: Warranty, Warranty Claim, & Return Policy

    Fountain online at: www.kascomarine.com/solutions_warranty_registration.htm , Kasco Marine will have a record of the purchase and will be able to determine whether or not the unit still car- ies warranty coverage. Once the warranty coverage has been established, the unit may be sent to any Kasco Authorized Repair Center...
  • Page 5 Any expedited shipping method for the return of the unit is at the customer’s expense. Kasco Marine will re- turn units repaired under warranty at our expense via ground freight within the continental United States.
  • Page 6: Maintenance Recommendations

    Seal replacement and all other repair services should be performed by Kasco Marine or a Kasco trained Au- thorized Repair Center. Any alterations or changes made to Kasco units by an unauthorized source will void the warranty.
  • Page 7 C-25 TIMER CONTROL INSTRUCTIONS Portable Timer with Ground Fault Interrupter (Unit: 9.8 FLA, 58.8 LRA 120 VAC Light: 300 W, 120 VAC) IMPORTANT This portable timer is designed for CONTROLLING the connected equipment only. Unplug timer before ser- vicing the unit or the equipment it controls. THIS SWITCH IS NOT TO BE USED AS A POWER DIS- CONNECT! For maximum protection against electrical shock hazard, perform test procedure on G.F.C.I.
  • Page 8 PARTS INCLUDED A. 1400JF Aerating Fountain (Assembled in box) (1) NOTE: If lights are not purchased or included, the cord and Transformer on the left side of the picture will not be included with the shipment. B. Interchangeable Nozzle Heads (Osprey Installed) (5) Osprey (Installed) Condor Falcon...
  • Page 9: Nozzle Options & Pattern Sizes

    1400JF NOZZLE OPTIONS & PATTERN SIZES The unique center set design of Kasco’s 1400JF Aerating Fountain nozzles offers the best clog-resistance and interchangeability available. To achieve the pattern you desire, simply select the appropriate nozzle according to the accompanying photos and install using the proper bolt or screw into the fountain tube or upper pump housing (depending on which nozzle chosen).
  • Page 11: Assembly & Installation Instructions

    If damages are found, immediately notify your top of the 4 Blade Prop. Place a slight amount of carrier and your Kasco Marine, Inc. representative. pressure on the new nozzle when in place and tighten Next, cross reference the parts included in the ship- the 1/4-20 x 7/8”...
  • Page 12 STEP SIX STEP EIGHT Use the ropes to position the Fountain in the desired Install the C-25 on the post with the power supply. location in the pond/lake. Anchor the ropes or secure Use up to three #10 x 1” long or longer screws and them to the shoreline so the ropes are free of slack, the molded screw placements on the C-25.
  • Page 13: Troubleshooting Tips

    TROUBLESHOOTING TIPS “ My Fountain trips the ground fault interrupter in the C-25.” This is the most common symptom of several possible problems. To correctly diagnose the problem, you will need to collect more information. A Ground Fault Interrupter (GFI) breaker that trips can in- dicate an electrical service problem, water contamination in the unit and/or cord, bad breaker, control box problems, motor problems, etc.
  • Page 14: Kasco Marine, Inc

    Fountain Warranty Information Please fill out the enclosed, addressed warranty card and mail to Kasco Marine, Inc. or register your fountain online at www.kascomarine.com/solutions_warranty_registration.htm . Also fill in the information below and keep for your records. Model # (Ex. 1400JF)_______________________________ Serial # (Ex.