Wieland samos User Manual page 33

Multifunctional safety switching device
Table of Contents

Advertisement

Function
Function display
Controls
Terminals
Max. number of modules / status in system
___________________________________________________________________________
Power circuitry (internal)
Operating voltage U
, DC
B
Residual ripple V
SS
Rated power, DC
___________________________________________________________________________
I1..I8
Input circuit (
)
Input voltage, U
E
Input current, I
E
Cyclical peak input current, I
Input capacitance, C
IN
Input resistance, R
IN
ON period*, t
E
OFF period*, t
A
Break time of U
(HIGH)
E
Break time period
Synchronous time t
(Functions 3, 5)
S
___________________________________________________________________________
(X1.. X8
Output circuit
)
Output voltage
Output current in sum
Wire capacitance, C
L
Wire resistance, R
L
Short-circuit behavior
___________________________________________________________________________
Input test
Test pulse width* t
;Test duration**, t
TI
Test pulse period, t
TP
Functions 1, 2, 3, 4, 5, 8
___________________________________________________________________________
Response times
Response time*** t
(normal operation)
AN
Function 1
Functions 6, 7
Functions 2 (without safety mat), 3, 4, 5, 8
Function 2 (safety mat)
© 2010 Wieland Electric GmbH | BA000256 | 12/2012 (Rev. I)
Input module in the samos system
11 green LEDs, 1 red LED
2 10-position switches
Plug-in terminals with screws / spring force
12 / slave on SBus
Min.
19.2 V
Min.
(HIGH)
13.0 V
(LOW)
–5.0 V
(HIGH)
2.4 mA
(LOW)
–2.5 mA
E,PEAK
70 ms
> t
AN
20 ms
Min.
18.0 V
Absolutely short-circuit-proof
t
, typ.
TI
;
TD
12 ms
Min.
SA-IN Input Module
Typical
Max.
24.0 V
30.0 V
3.0 V
1.2 W
Typical
Max.
30.0 V
5.0 V
3.0 mA
3.8 V
2.1 mA
15 mA
200 nF
8 k
1.0 ms
1500 ms
Typical
Max.
30.0 V
150 mA
1000 nF
100 
t
, typ.
t
, typ.
TD
TP
20 ms
40 ms
Typical
Max.
33 ms
16 ms
24 ms
42 ms
Technical data
SA-IN
* For the times see the
function diagrams at the
end of the table.
The sum of currents,
which are drained from
all input modules of one
system to supply external
sensors, may not exceed
600 mA!
* Signal changes are not
detected during the test
pulse.
** Signal changes from
HIGH to LOW are not
detected during the test.
For the times see the
function diagrams at the
end of the table.
*** The response time t
AN
is the time between the
output signal arriving at the
input terminals and the
semiconductor outputs of
the associated base
module actually being shut
down. The time is
independent of the
number of input modules
connected to the base
module.