Natural Gas Hose Connection
1. Remove the LP gas hose and regulator using a wrench, and attach the natural gas hose in it's place.
(Fig. 7)
/
NG Hose
LP gas hose and regulator
Fig. 7
Adjust valve control screw
,
Pull all the knobs off of valve stems. Adjust
the screw in the valve hole using the
flathead screwdriver. Turn screws two
complete turns counterclockwise.
(Fig. 8)
Valve hole
Fig. 8
2. Press all the knobs back onto valve stems.
3. After all the conversions are complete, return heat diffusers to firebox, followed by the grates and warming
rack.
33