SECTION 1 General Information
Description
The IntelliZone
Commercial Ozone Gererator (Models
CD-15G and CD-25G (521659, 521660, 521761 and
521762) described in this manual is designed to provide
the benefits of ozonated water in an environmentally
safe and effective manner. The high quality, specially
engineered components ensure efficient ozone output
and reliable performance.
Thos ozone generator is safe and harmless
to your equipment if installed properly.
24.1 613
A
12.3
311
24.4 620
39.2 995

MOUNTING

BRACKETS (2)
Figure 1

Specifications

For detailed specifications refer to the ozone
generator specification label located on the inside
of the door on the unit.
Location Requirements*:
Mounting: Floor or wall mount in a clean, protected
area using supplied brackets.
Ventilation: Room should provide 6 air changes
per hour
Ambient Temp.: 40–100˚F (5–38˚C)
* Protection from weather elements must be provided
for outdoor installations. Operating outside of the
recommended temp. ranges may result in damage
not covered under the manufacturer's warranty.
A
DIM "A" = 6 [152] MIN CLEARANCE
DOOR SWING
R24.5
11.7 297
MIN. CLEARANCE
4.0
102
(IF WALL MOUNTED) 4.0 102
INTELLIZONE™ COMMERCIAL OZONE GENERATOR Installation and User's Guide
SECTION 2 Installation
Location
The ozone generator is designed for either floor or wall
mounting in a clean, protected area, either indoors or
outdoors. Locate generator out of reach of sprinklers or
drainage spouts. Allow sufficient access for maintenance
and all tubing and electrical wires. The generator must
not be placed in locations where ambient ozone levels
exceed 0.01 PPM.
Mounting
NOTE: Do not remove compressor packing
material until unit has been mounted.
Wall Mount Option
1. Attach two mounting brackets to wall using
anchors appropriate for mounting surface.
See Figure 2.
621
2. Using 1/4"-20 bolts (with washers as shown)
secure generator to mounts.
Floor Mount Option
1. Use the four 1/4"-20 bolts with washers to
secure feet to bottom of cabinet.
2. Stand upright and securely fasten to concrete
slab using appropriate anchors and bolts.