Ninglu FS117 Operation & Installation Manual

7 inch dual-frequency fish finder

Advertisement

Quick Links

7 inch Dual-Frequency

Fish Finder

FS117
Model:
Operation & Installation Manual
Document: NLT-FS117-SSEN
Version: V120905

Advertisement

Table of Contents
loading

Summary of Contents for Ninglu FS117

  • Page 1: Fish Finder

    7 inch Dual-Frequency Fish Finder FS117 Model: Operation & Installation Manual Document: NLT-FS117-SSEN Version: V120905...
  • Page 2: Table Of Contents

    Content Introduction ..............1 Theory of fish finder ..................1 Operation ..............2 Screen ......................2 Keyboard ......................3 POWER ..................3 BACKLIGHT ................. 3 MENU ................... 3 RANGE ..................3 GAIN ..................... 3 FREQ .................... 4 ZOOM ................... 4 RELAY ..................
  • Page 3: Introduction

    Introduction Thank you for choosing our fish founder—FS117 The FS117 is a high quality, dual-frequency fish finder. It uses TFT LCD to provide a color display for easy daylight viewing that can be dimmed for night fishing. With 8 or 12 colors bar, the colors represent different signal strengths, making the displays easy to recognize the bottom and fish schools.
  • Page 4: Operation

    Operation Screen Picture feed speed 2. Depth Time marker (one yellow line indicates 30s) Basic range 5. Fish school or other objects First reflection echo 7. Second reflection echo Gain (H: 200 kHz, L: 50 kHz) 9. Color bar 10. Zoom mode display area Bottom lock zoom mode Layer zoom mode 11.
  • Page 5: Keyboard

    Operation Keyboard POWER Turn the power supply on/off. BACKLIGHT Adjust the LCD backlight. MENU Press【MENU】to display the menu items. Then select a particular option. Using the 【▲】or【▼】, and use【 】or【 】to adjust the setting value. Press【MENU】again to save the setting and quit from menu. RANGE 】...
  • Page 6: Freq

    Operation FREQ Press【FREQ】to select display mode: 1. 200 kHz display mode 2. 50 kHz display mode 3. Dual-frequency display mode ZOOM Firstly, choose Zoom mode in MENU, see page 7 ~ 8. Bottom-lock zoom Mode Press【ZOOM】to choose zoom rate: OFF, ×2, ×4, ×8 Layer Zoom Mode The screen is divided into 4 layers, press【ZOOM】to choose the layer expanded.
  • Page 7: Menu

    Operation Menu Menu item Default Setting value 0, 1/4, 1/2,1/1,2/1,4/1 【 】 _RANGE OFF, ON 【 】 OFF, LO , HI 【 】 OFF, LO , HI 【 】 OISE EJECTION ZOOM 【 】 TOM-LOCK ZOOM, ZOOM FISH Al OFF, ON 【...
  • Page 8: Pic

    Operation Set the picture feed rate (to the left): 0, 1/4, 1/2, 1/1, 2/1, 4/1. _RANGE “A _RANGE” means Auto-range; the basic range will change automatically to always show the full depth from transducer face to bottom regardless of changes in depth. When “A_RANGE”...
  • Page 9: Noise Rejection

    Operation OISE EJECTION is to reject noise interference from nearby fishing vessels. OISE EJECTION Each press of the 【 】or【 】key changes the ability for rejecting the interference as follow: ZOOM Bottom-lock zoom Mode If Bottom lock zoom is on, the zoom section moves so the bottom is always displayed in the zoom section, regardless of changes in depth.
  • Page 10: Fish Alarm

    Operation mode. When the Bottom lock zoom is on, “ ” will show on the screen. Press【MODE】to choose zoom rate: OFF, ×2, ×4, ×8 Layer Zoom Mode The screen is divided into 4 layers, press【MODE】to choose the layer expanded. Layer zoom is not available in dual-frequency mode or range relay mode. When the layer zoom is on, it will display “...
  • Page 11: Colors

    Operation COLORS There is a choice of the colors bar: 8 colors or 12colors 8 colors bar: Red, orange, yellow, green, light green, lake blue, light blue, dark blue 12 colors bar: Dark red, red, orange, ochre, yellow, light green, green, light blue, cyan, gray, purple, blue.
  • Page 12: Installation

    Installation Operator unit Unit: mm...
  • Page 13: Transducer

    Note of operator unit installation 1. Avoid direct sunlight, shock and vibration. 2. Power supply should be steady to avoid damage of high voltage. 3. Operator unit should be far away from the equipments which generate electromagnetic radiation, such as: motors, generators. Transducer Transducer in the air must be avoided! This may cause mechanical damage of the element.
  • Page 14: Specifications

    Specifications Item Specification 7 inch TFT, 480×234 pixel Display 200kHz /50kHz Frequency 4 8 24 40 56 80 120 160 200 240 280m Range 600W: BP60-200-15L Output Power Time scale Meter, Fathom Depth Unit 8 or 12 colors Echo intensity Fish alarm(>2m), Shallow water alarm (>0.8m) Alarm types 11.6VDC ~39VDC...
  • Page 15 Principle of Dual-frequency Working...

Table of Contents