Dinex IRAC15 Operating & Maintenance Manual

Dinex IRAC15 Operating & Maintenance Manual

Air curtain refrigerator

Advertisement

Air Cu rtain
R e f ri g e rato r
O pe rating & Ma i nte n a n ce Ma n u a l
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Parts Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Unit Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Dinex® Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
For Service Information, call 1-888-673-4639
Please provide following information:
• Model number
• Serial number
• Part Description and number as shown in parts list.
Printed in the USA
DINEX INTERNATIONAL, INC. • 628-2 HEBRON AVENUE, GLASTONBURY CT 06033 • WWW.DINEX.COM
Model: IRAC15
Manual No. IRAC15-2 Rev-01/07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IRAC15 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dinex IRAC15

  • Page 1: Table Of Contents

    Please provide following information: • Model number • Serial number • Part Description and number as shown in parts list. Manual No. IRAC15-2 Rev-01/07 Printed in the USA DINEX INTERNATIONAL, INC. • 628-2 HEBRON AVENUE, GLASTONBURY CT 06033 • WWW.DINEX.COM...
  • Page 2: Introduction

    Should you have any questions concerning • 120 Volt 20 amp (NEMA 5-20P) power source is required. the Equipment, please call the Dinex Hotline at 1-888-673- 4639 (Monday through Friday from 8 am to 5 pm, Eastern • Ambient room temperature must not exceed 80 F.
  • Page 3 5. Use the ca l i b ra tion po te nt i o m e ter to adjust to 32° F (0° C) Due to va rious conditions such as ext remely high ki tc h e n te m pe rat u re, high fre q u e n cy of tray act i v i ty bre a king the 6.
  • Page 4: Maintenance

    2. Vinyl trim should be washed with a chlorine-free deter- REFRIGERATION & ELECTRICAL SPECIFICATIONS gent and water. Rinse thoroughly with clear water and allow to dry. Never use abrasive cleaners, waxes, car pol- Refrigeration ish, or substances containing strong aromatic solvents or Refrigerant Type: R134A alcohol.
  • Page 5 RANCO THERMOSTAT TEST PROCEDURE 8. Using an ohm meter, check the door switch, measuring across the two terminals pointing in the same direction (the "Common" and the "Normally Closed") the switch A Voltmeter and a Pyrometer (temperature meter) will be should be open when the switch is depressed and required for this procedure.
  • Page 6: Troubleshooting

    3. Check to see that the condensing unit is plugged into Troubleshooting the electrical box located in the lower housing. 4. Disconnect the condensing unit plug and plug it into an AIRSCREEN REFRIGERATOR T RO U B L E S H O OT I N G external power supply.
  • Page 7 Cart Not Cooling Is the condensing unit plugged into the receptacle box? Plug condensing unit in. *Is the RANCO thermostat operating correctly? NO Correct the problem. (See "RANCO thermostat test proce- dure") Is the cart freezing up? YES Correct the problem. ( See "air screen re f ri g e rator tro u b l e s h ooting - ca rt fre ezing up") Figure 2 *Is the condensing unit operating correctly? NO...
  • Page 8 Figure 4 Figure 5 7. Remove door catch mechanism located on the side of the cabinet and relocate it to the opposite side. 8. Use fasteners and filler plates to fill left over openings and open threaded holes. Page 8...
  • Page 9: Unit Diagram

    Unit Diagram Page 9...
  • Page 10: Wiring Diagram

    Page 10...
  • Page 11: Replacement Parts

    Replacement Parts De s c ri p t i o n Pa rt Nu m be r De s c ri p t i o n Pa rt Nu m be r 18614-0051 Ac c u m u l ator 5/8 Suct 18302-0050 L atc h , Door Mag &...
  • Page 12: Dinex Warranty

    OF DINEX’S REPRESENTATIVES SHALL MODIFY OR EXPAND T H E S E • Co nveyer Prod u ct s WA R RA N T I E S .DINEX AND DINEX’S AFFILIATES AND REPRESENTAT I V E S • Tray and Other Ca rt Prod u ct s...

Table of Contents

Save PDF