Download Print this page

Holatron RFLS-MK3HSXT Operation & Maintenance Manual page 9

Acoustic triggered high speed uhf transmitter

Advertisement

Xmtr Digital
Switch Setting
Enables transmission of a semi-
0
automatic fire command upon
detection of acoustic event or upon
"Fire B" button depression. Minimum
acoustic threshold (maximum
acoustic sensitivity).
Same as above with higher acoustic
1
threshold.
Same as above with higher acoustic
2
threshold.
Same as above with higher acoustic
3
threshold.
Same as above with higher acoustic
4
threshold.
Same as above with higher acoustic
5
threshold.
Same as above with higher acoustic
6
threshold.
Same as above with higher acoustic
7
threshold.
Same as above with higher acoustic
8
threshold.
Same as above with higher acoustic
9
threshold.
Same as above with higher acoustic
A
threshold.
Same as above with highest acoustic
B
threshold (minimum acoustic
sensitivity).
Semi-automatic firing.
C
(Single shot, sequential)
Semi-automatic firing.
D
(Single shot, sequential)
Semi-automatic firing.
E
(Single shot, sequential)
Semi-automatic firing.
F
(Single shot, sequential)
"Fire A / Enable B" Action
If "Fire A" button is also pressed,
xmts a semi-automatic (single-shot)
fire command continuously until
one or both buttons are released.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Same as above.
Automatic firing (rapid fire) at a rate
of 7.69 shots / second while the
button is pressed. (0.13 second per
shot)
Automatic firing as above at a rate
of 10 shots / second. (0.1 second
per shot)
Automatic firing as above at a rate
of 14.3 shots / second. (0.07
second per shot)
Automatic firing as above at a rate
of 20 shots / second. (0.05 second
per shot)