WHEN INSTALLING AND CONNECTING THE APPLIANCE TO THE GAS SUPPLY,
ENSURE THAT THE GAS SUPPLY HOSE IS NOT TWISTED, STRETCHED OR
SUBJECTED TO ANY FORM OF STRAIN WHICH COULD CREATE A HAZARD.
The gas supply pipe connected to the appliance must be a rigid metal pipe with sealed fittings. It is possible to fit
a flexible hose, however, in this case the following conditions must be respected:
a) The hose can be accessed easily for inspection;
b) The hose must be protected against coming into contact with parts which heat up (for example parts
underneath the burners);
c) The hose must be protected against being damaged (twisting, pulling, trapping,....);
d) The hose must be protected against being trapped by moving parts (e.g. drawers);
e) The hose must not have a length over 1.5 m;
f) The hose must be replaced before its expiry date;
For models PI8621A, PI8621S, PI8621R seal the appliance gas pipe utilising the sealed tube with pre-mounted
gas fitting provided. Once the appliance has been connected to the gas supply check for gas leaks utilising a non-
corrosive fluid. Do not use a water and soap solution. NEVER USE A FLAME TO TEST FOR GAS LEAKS
Models PI8621A, PI8621S and PI8621R are modular. It is possible to connect from 1 to 5 appliances in series.
Disconnect and remove the sealed tube mounted to the gas pipe on the installed appliance and connect it to the
gas pipe on the appliance to install. Connect the appliances together by connecting the gas pipes in series utilising
the fitting.
CONNECTING TO ELECTRICITY SUPPLY
This chapter refers only to models with the wording 12 VDC on the appliance specifications label affixed to the
appliance.
THIS APPLIANCE MUST BE CONNECTED TO A 12 VDC POWER PACK ONLY. THE
CIRCUIT MUST BE FITTED WITH A SAFETY FUSE NOT HIGHER THAN 3 AMP.
WHEN WIRING RESPECT CORRECT POLARITY!
IT IS OF UTMOST IMPORTANCE NEVER TO CONNECT THIS APPLIANCE TO MAINS
VOLTAGE (230 V) WHICH IRREVERSIBLY DAMAGES APPLIANCE COMPONENTS AND
CREATES A HAZARD TO THE USER.
To connect the appliance use a 1.5 mm
rear of the appliance. The red terminal is the positive pole and the black terminal is the negative pole.

FIXTURE

THIS APPLIANCE MUST BE FITTED AND SECURED TO THE CABINET UTILISING THE FIXTURE SCREWS AS
ILLUSTRATED IN FIG. 3 - PG.131.
2
double red and black wire and wire to the terminal junction box located at the

Hide quick links: