Download Print this page

Competition SAC5B-CK Operation And Installation Manual page 15

Advertisement

1. Cables of LCC system:
Non-wired cable.
2
mm , from outdoor station to the farthest monitor distance 70m.
2. Each monitor should be parallel connected. One monitor can be
extended 3 monitors as maximum extension. One monitor can be
connected 2 outdoor stations as maximum.
3. Handset monitor only has 2 functional buttons. Hand-free monitor
only has 2 functional buttons, not available for transferring-call
function.
4. Built-in power supply video door phone can working with input AC
votage directly. Non-built-in power supply needs plus a power
supply the specification is DC 14.5V 1.3A.
-35-
Diameter
0.5
MODEL: SAC25B/C-CK
Voltage: DC 14.5V
Working current:100mA Stand by: 10mA
.
Mode: dual transmission
Transmission distance 28m, wire 0.2mm
.
Transmission distance 50m, wire 0.3mm
Transmission distance 70m, wire 0.5mm
.
Dimension: 90x130x43mm (involve waterproof)
MODEL: SAC5B/C-CK
Voltage: DC 14.5V
Working current:100mA Stand by: 10mA
Mode: dual transmission
Transmission distance 28m, wire 0.2mm
Transmission distance 50m, wire 0.3mm
Transmission distance 70m, wire 0.5mm
MODEL: SAC50B/C-CK
Voltage: DC 14.5V
Working current:100mA Stand by: 10mA
Mode: dual transmission
Transmission distance 28m, wire 0.2mm
Transmission distance 50m, wire 0.3mm
Transmission distance 70m, wire 0.5mm
SAC35B/C-CK
o
Temperature: -20 +55 C
Talking time: 2 minutes
2
2
2
SAC551B/C-CK
o
Temperature: -20 +55 C
Talking time: 2 minutes
2
2
2
SAC561B/C-CK
o
Temperature: -20 +55 C
Talking time: 2 minutes
2
2
2
-36-