Entritech series hands free /handset indoor monitors

Advertisement

Link Settings & Options
The default setting is J1, J2 and J3 are all linked.
J1 linked---When outdoor panel calls the indoor monitor, the sounder on outdoor panel will
also operate.
J2 linked---amplifies the video signal. If you connect 2 or more indoor monitors, link the
jumper J2 of the farthest monitor and remove the jumper J2 on the other monitors.
J3 linked---Call button illuminated
Multiple monitor link settings
ST
1
MONITOR
J3
LINK
LINK
J1
J2
Page 5 of 10
nd
2
MONITOR
J3
J1
J2
rd
3
MONITOR
J3
J1
J2
th
4
MONITOR
J3
J1
LINK
J2
EntriTech HF issue 1