Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang Uniview Technologies Co., Ltd. All rights reserved. No part of this manual may be copied, reproduced, translated, or distributed in any form or by any means without prior consent in writing from our company.
Page 3
contents of this manual are subject to change without prior notice. Update will be added to the new version of this manual. Use of this manual and the product and the subsequent result shall be entirely on the user's own responsibility. In no event shall we be liable for any special, consequential, incidental, or indirect damages, including, among others, damages for loss of business profits, business interruption, or loss of data or documentation, or...
Safety and Compliance Information Safety Symbols The symbols in the following table may be found on installation-related equipment. Be aware of the situations indicated and take necessary safety precautions during equipment installation and maintenance. Symbol Description Generic alarm symbol: To suggest a general safety concern.
Page 5
This device is a class A product and may cause radio interference. Take measures if necessary. While shipping, the device should be packed in its original packing. Disconnect power before installation and cable connection. Power down the device before connecting and disconnecting cables, accessories and peripherals.
Internet). Possible risks and consequences are at user's sole discretion. Contact your dealer if the device does not work properly. Never attempt to disassemble the device yourself. User shall assume all responsibility for damage, loss, or injury caused by unauthorized repair or maintenance.
Page 7
This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. LVD/EMC Directive This product complies with the European Low Voltage Directive 2006/95/EC and EMC Directive 2004/108/EC. WEEE Directive–2002/96/EC The product this manual refers to is covered by the Waste Electrical & Electronic Equipment (WEEE) Directive and must be disposed of in a responsible manner.
Introduction This manual describes how to manage the device on a Web browser. The figures in this manual are only for illustration purpose. The parameters, options and values actually displayed on the Web pages of your device may be different from those in this manual. Login Before you start, check that: The device is operating properly.
Common Functions The Common page lists functions that are frequently used to manage the device. The table below describes the meaning of the icons on this page. Icon Description View the basic device information, including device model, firmware version, network settings, and management mode. For more details, see Device Status.
Icon Description Set network parameters such as IP address for the device. For more details, see TCP/IP. Set parameters required if the device is to be managed by a management platform (central server). For more details, see Management Platform. Set vidoe output parameters, including the number of windows that appear on the screen, image resolution and refresh rate.
Set the parameters. Some are described in the table below. Parameter Description Static IP: Assign an IP address, subnet mask and default gateway for the device. The IP address must Obtain IP By be unique on the network. DHCP: Use the DHCP server to assign an IP address. ...
Click Network > Telnet. Select the check box to enable Telnet, and then click Save. SNMP Enable Simple Network Management Protocol (SNMPv3) if the device operates in server mode (managed via a central server). Through SNMP central server synchronizes audio/video channel configurations and some of the scheduled tasks to the device, and the device reports device alarms to the central server.
Page 14
Parameter Description Enable SNMPv3 Enable or disable SNMP as needed. Authentication mode for access from the central server. Authentication Mode Default: MD5 Authentication Authentication password for access from the Password central server. Default: Snmp@123 Confirm Password Encryption method used for access from the central server.
Audio and Video Set video, audio and media stream parameters. The major functions provided on the Video & Audio menu are listed in the table below. Submenu Function Audio Mute or adjust sound volume. Set the number of windows on the screen. ...
Video Select the output channel and then set the number of windows on the screen, image resolution and refresh rate. Click Audio & Video > Video. Set the parameters and then click Save. Media Stream Set media stream parameters, including the stream source address and address format, so that the device can receive media streams from the connected cameras.
Set the parameters. Some are described in the table below. Parameter Description Output Channel Video output channel. Stream Address Address of the media stream source. (Window 1) Stream Address Address format for User Datagram Protocol (UDP). Format(UDP) Stream Address Address format for Real Time Streaming Protocol Format(RTSP) (RTSP).
Page 18
Set the parameters. Some are described in the table below. Parameter Description Display Ratio Set the image display ratio. Crop Upper Edge(pix) Crop Lower Edge(pix) Crop images as needed. Crop Left Edge(pix) Crop Right Edge(pix) Divider Line Color Set the width and color of the divider line on the screen.
Transparent Channel Set the transparent channel to transfer video and audio signals through a serial port. Click Service > Transparent Channel. Set the parameters. Some are described in the table below. Parameter Description Transparent Enable or disable transparent channel. Channel Port Port used for transparent channel.
System Set system parameters, including the user password, system time, system language, management platform, and serial port. User Change the default password to a strong one (at least 8 digits) after your first login. It is also recommended that you change the password periodically to ensure account security.
Set the parameters. Some are described in the table below. Parameter Description Time Zone Choose a time zone for your device. Enable this function if you have a Network Time Protocol (NTP) server on the network. The device synchronizes time Auto with the NTP server at the set interval when enabled.
Select Connect to Platform. Set the parameters. Some are described in the table below. Parameter Description Device ID Must be unique on the network. Protocol Private: Private protocol used to manage the device. IP address of the central server. Server IP Must be consistent with the server address.
Page 23
The figure below shows the parameters displayed when COM 2 is selected. Some parameters are described in the table below.
Parameter Description Port Select the serial port to set. Port Type RS232 or RS485/422 interface. Available only when Port is set to COM 2. Transparent Channel: Used for data transfer between the Port Mode device and a third-party device; available only when Port Type is set to RS485/422.
Submenu Function Export logs. Upgrade the software. View device information, including device model, version, Device Status network settings, and management mode. View decoding status, including output channel, number of Decoding windows on the screen, display mode, and remaining Status decoding capacity.
Decoding Status Click Maintenance > Decoding Status to view decoding status, including the output channel, number of windows on the screen, image resolution and refresh rate, remaining decoding capacity, and stream source address. The following shows an example.