Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Datron Manuals
Multimeter
1062
Service handbook
Autocal' Over - Datron 1062 Service Handbook
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
page
of
202
Go
/
202
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
11
1.8
'AUTOCAL'
OVER THE BUS
All
the
calibration
procedures covered
in
this
manual
can be
carried
out remotely
using
Option
50, the
IEEE
Bus.
Effectively,
the
five
calibration
keys
are
replaced
by
five
Bus
instructions
and
these are
used
instead of
the
'CALIBRATE'
keys
listed
in
the Calibration
tables
on
previous
pages.
An
example
of calibration
with the
Bus
is
given
in
the
table
below.
A
complete program
listing
for
the
same
calibration
operation
assuming an
HP9825
controller
is
as
follows:
0;
dim DS[15]
1:
clr728
2:
wrt
728,"F3R3Q1W1="
3:
O-^'S
4:
wrt
728,"G0="
define
15
character
string
variable
send
'device
clear'
to
DVM
(interface
7,
address 28)
program
to
DC
IV,
SRQ
Mode
1,
Enable
Cal.
program
zero
cal.
trigger
5:
oni
7,"srq"
6:
eir
7,128
7:
if
bit
("01XXXXXX'
,S)
=0;jmp
—1
8:
dsp
"Apply IV
&
CONTINUE"
9:
0-^S;stp
10:
wrt 728,
"G1="
11:
oni
7,"srq"
12:
eir
7,128
13:
if
bit
("01XXXXXX'
,S)
=0:jmp
—1
14;
wrt
728,"T0W0="
15:
Id
728
16: stp
17:
"srq":rds(728)->S
18:
red
728,
DS
19:
iret
*7717
jump
to
SRQ
service
routine
on
interrupt
enable
SRQ
interrupts
from
interface 7
check
status
byte
S
obtained by
service
routine
prompt
operator
to
apply
calibration
source
on
com-
pleting
zero
cal
program
gain
cal.
trigger
program
to
Internal Trigger,
Disable
Cal.
on completion
of gain
cal.
program
DVM
to
local
state
SRQ
service
routine to read
status
byte
CALIBRATION
EXAMPLE
USING THE BUS
Step
Calibration
Operation
Calibration
Source
DVM
Setting
Bus
Controller
Instruction
DVM
Reading
After
Calibration
Remarks
1
Set
DVM
to
known
state
In
Remote
State
'Device
Clear'
Program
DVM
to
predetermined
state
A0C0DXE0F3M0N0
O0P0Q0R6S0T5
2
Set
DVM
to
DCV, IV
Range, and
prepare
for
calibration
-(-O.OOOOOV
Calibration
key
to
'CAL'
'F3R3Q1W1='
Program
DVM
to
Function:DC V(F3)
Range:1V
(R3)
SRQ
Mode
1
(Q1)
Enable
Cal.
(W1)
3
IV
Range
Zero
-^O.OOOOOV
In
Remote
State
'G0='
±.ooooov
Program
'Zero'
cal.,
SRQ
indicates
when
calibration
operation
completed
4
IV
Positive
Full
Range
-1-
1.00000V
In
Remote
State
'G1='
-(-1.00000V
Program
'Gain'
cal.,
SRQ
indicates
when
calibration
operation
completed
5
Set
DVM
to
Internal
Trigger,
Disable
Cal.
In
Remote
State
'T0W0='
Program
DVM
to
Internal
Trigger
(T0),
Disable
Cal.
(W0)
6
In
Local
State,
Calibration
key
to
'RUN'
'Local'
DVM
in
normal
mode,
free-running
Table of
Contents
Previous
Page
Next
Page
1
...
17
18
19
20
21
22
23
24
Show Quick Links
Quick Links:
Calibration
Table of Contents
DC Voltage
User's
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Related Manuals for Datron 1062
Measuring Instruments Datron 1061 Calibration And Servicing Handbook
(197 pages)
Measuring Instruments Datron 1061A User Handbook Manual
Digital voltmeters (73 pages)
Multimeter Datron 4708 User Handbook Manual
Autocal multifunction standard (150 pages)
Related Content for Datron 1062
4708 The Datron 4708 Autocal Multifunction Standard
Datron 4708
This manual is also suitable for:
1061a
1061
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL