What to do if water escapes from the
appliance
Danger
When water escapes from the
appliance there is a risk of elec-
trocution.
Switch off the heating system by
means of an external isolator (for
example fuse box, domestic
power distribution).
Flue systems and combustion air
Ensure that flue systems are clear and
cannot be sealed, for instance due to
accumulation of condensate or other
causes. Ensure an adequate supply of
combustion air.
Instruct system users that subsequent
modifications to the building characteris-
tics are not permissible (e.g. cable/pipe-
work routing, cladding or partitions).
Danger
Leaking or blocked flue systems,
or an inadequate supply of com-
bustion air can cause life threat-
ening poisoning from carbon
monoxide in the flue gas.
Ensure the flue system is in good
working order. Apertures for sup-
plying combustion air must be
non-closable.
Extractors
Operating appliances that extract air to
the outside (cooker hoods, extractors, air
conditioning units, etc.) can create neg-
ative pressure. If the boiler is operated at
the same time, this can lead to reverse
flow of the flue gas.
4
(cont.)
Danger
The simultaneous operation of
the boiler and appliances that
extract air to the outside can
result in life threatening poison-
ing due to reverse flow of the flue
gas.
Fit an interlock circuit or take suit-
able steps to ensure an adequate
supply of combustion air.