Pioneer PDP-424MV Service Manual page 34

Table of Contents

Advertisement

5. Operation check
After replacing the module or parts inside the module, perform aging for 30 minutes or more
while displaying a fully white screen.
After that, check the screen by displaying a fully red, fully green, and fully blue screen, color
bars, and gray scale.
Note: If any flashing or luminescent spots are recognized during display check after a long period of
storage of the module, perform aging with a fully white screen displayed for another hour or so.
34
7-12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp-42mve1

Table of Contents