3.3 Digital Torque Amplifier Installation
3.3 Digital Torque Amplifier Installation
The SGDG digital torque amplifier is a base-mounted digital torque amplifier. Mount it
properly according to the following cautionary items as mistakes in the mounting method can
lead to failure of the unit.
■ Storage Conditions
Store the digital torque amplifier within the temperature range below when storing
without electrical feed.
Temperature Range: -20~ +85°C
■ Mounting Conditions
Location
The following points should be kept in mind with regard to the mounting location.
Installation
Conditions
Mounted in a Control
Panel
Mounted Near a Heat-
Generating Object
Mounted Near a
Vibration Source
34
LEGEND SGDG Digital Torque Amplifier
Cautions on Mounting
Design the control panel size, digital torque amplifier
installation, and cooling method so that the ambient
temperature of the digital torque amplifier does not exceed
55
.
°C
Suppress the temperature rise due to radiated heat and
convection from the heat-generating object so that the
ambient temperature of the digital torque amplifier does
not exceed 55
.
°C
Attach vibration-preventative brackets to the digital torque
amplifier mounting surface so that the vibrations are not
communicated to the digital torque amplifier.