Panasonic EY75A7 Operating Instructions Manual page 12

Hide thumbs Also See for EY75A7:
Table of Contents

Advertisement

Available languages

Available languages

LED Light
EN
Press the light button and set illumination
condition.
Illuminated
Illuminates by pressing button.
The light turns off when the tool
has not been used for more
than 5 minutes or just after
attaching the battery pack.
Depress the trigger switch and
operate the tool once.
Interlocking trigger
Illuminates when depressing the
trigger switch.
Turns off when the trigger is
released.
Off
The light illuminates with very low current,
and it does not adversely affect the perfor-
mance or its battery capacity.
CAUTION:
• The built-in LED light is designed to
illuminate the small work area tempo-
rarily.
• Do not use it as a substitute for a
regular flashlight, since it does not
have enough brightness.
CAUTION: DO NOT STARE INTO
BEAM.
Use of controls or adjustments or perfor-
mance of procedures other than those
specified herein may result in hazardous
radiation exposure.
Overheat warning
Off
(normal
operation)
Indicates operation has been halted due to
motor or battery overheating.
To protect the motor or battery, be sure to
note the following when carrying out this
operation.
• If the motor or battery becomes hot, the
protection function will be activated and
the motor or battery will stop operating.
The overheat warning lamp on the
control panel illuminates or flashes when
this feature is active.
• If the overheating protection feature
activates, allow the tool to cool thorough-
ly (at least 30 minutes). The tool is ready
for use when the overheat warning lamp
goes out.
• Avoid using the tool in a way that causes
the overheating protection feature to
activate repeatedly.
• If the tool is operated continuously under
high-load conditions or if it is used in
hot-temperature conditions (such as
during summer), the overheating protec-
tion feature may activate frequently.
• If the tool is used in cold-temperature
conditions (such as during winter) or if it
is frequently stopped during use, the
overheating protection feature may not
activate.
The performance of the EY9L42 deterio-
rates significantly at and below 10°C due
to work conditions and other factors.
Battery Level Indicator
Press the battery level button.
Battery level indicator shows battery level
in three levels while pressing the button.
It shifts to Impact power mode when
release the button.
- 12 -
Illuminated:
Flashing:
Overheat
Overheat
(motor)
(battery)

Advertisement

Table of Contents
loading

Table of Contents