US E R M AN UA L
Type OCC3 / OCD3
57695 05/08 - (BJ)
Introduction
The thermostat is capable of switching on your heating system at pre determined times on different days of the week. It is possible to set 4 periods called
events each day with different temperatures. From factory a default schedule is programmed suitable for most installations. Unless you change these
settings the thermostat will operate to this default program.
Working with lower temperatures during times that the room is unoccupied will lower your energy costs without reducing the comfort. The thermostat has an
adaptive function that automatically changes the start time of a heating period so that the desired temperature is reached at the time that you set. After 3
days the adaptive function has learned when the heating must be switched on.
The thermostat has a built-in temperature sensor and an externally temperature sensor. In this configuration the thermostat controls the temperature within
the room and use the externally temperature sensor as limit sensor avoiding too high or too low temperatures in the floor construction.
The thermostat has a pin button marked R, allowing you to reset the thermostat to factory settings. These are listed at the end of this manual with space for
you to record your own weekly schedule.
The display is backlit when operating the buttons. The heating element is switched off when the light is on in the display.
The heating system can be switched off on the built-in interrupter. The Microprocessor taking care of the time will still be supplied with power whereby time
and day will be maintained. When the heating is required and the thermostat is switched on, it will continue the 4-event programme based on present time
and day.
1. Getting started
Buttons
A:
B:
C:
Pin button
On/off
Reset to
adjust of
factory
clock
setting
E:
F:
G:
OK -
Adjustment
Display
accept
up
Setting the thermostat into operation
First time power is connected the clock and day will be flashing and must be set. If you need to
adjust the time of the thermostat at a later date, insert a pin into the hole
and day. Adjustment must be made for summer and winter time.
Press the UP (
select the correct time and press OK button (
Then press the UP (
select the correct day and press OK (
Type: OCC3 / OCD3
English
D:
Adjustment
down
) or DOWN (
) buttons to
) or DOWN (
) button to
) button.
Display symbols
H
I
J
K
H:
I:
J:
Clock
Manual
Time and
function
mode
temperature
L:
M:
N:
Heating on
%
4-event symbol
Monitoring
of switch-on
time
for setting of time
).
1-7
N
M
L
K:
Day number
Wake
Out
Night
Home
1

Advertisement

loading

Summary of Contents for OJ Electronics OCC3

  • Page 1 US E R M AN UA L Type OCC3 / OCD3 57695 05/08 - (BJ) English Introduction The thermostat is capable of switching on your heating system at pre determined times on different days of the week. It is possible to set 4 periods called events each day with different temperatures.
  • Page 2 2. Daily use of the thermostat 4-event clock mode The day has been split into 4 events describing a typical day. When the thermostat is in 4-event mode it will automatically adjust the temperature according to the required temperature to the required time. As standard the thermostat has 5 days with 4 events, and 2 days with 2 events. Programming see 3. 4-event clock mode: The clock function symbol ( ) and one of the 4-event symbols (...
  • Page 3 Type OCD3 can be changed into type OCC3-1991 with an external temperature sensor that normally is placed in the floor construction. In this configuration the thermostat controls the temperature of the floor and not the temperature within the room. OCD3 can also be changed into type OCC3-1999 with a built-in temperature sensor.
  • Page 4 “Setting the thermostat into operation”. Note that a OCD3 that has been modified to a OCC3 (see 4. Advanced settings and read-out, selection of type) will return to a OCD3. Failure code E2 will be displayed if the external sensor has been removed.
  • Page 5 GEB RU IK S H AN D L E I D IN G Type OCC3 / OCD3 Nederlands Inleiding De thermostaat kan uw verwarmingssysteem aanzetten op vooringestelde tijden op verschillende dagen van de week. Er kunnen elke dag 4 perioden met verschillende temperaturen worden ingesteld die als standen worden aangeduid.
  • Page 6 2. Dagelijks gebruik van de thermostaat 4-standen instelling klok De dag is in 4 standen ingedeeld die een typisch verloop van een dag voorstellen. Wanneer de thermostaat in de 4-standen instelling staat, zal hij de temperatuur automatisch afstellen op de op die tijd gewenste temperatuur. De thermostaat heeft als standaard 5 dagen met 4 standen en 2 dagen met 2 standen.
  • Page 7 Type OCD3 is te veranderen in type OCC3-1991 met een externe temperatuursensor die gewoonlijk in de vloerconstructie wordt aangebracht. In deze configuratie regelt de thermostaat de temperatuur van de vloer en niet de temperatuur in de kamer.
  • Page 8 De tijd en dag worden ook gereset en moeten worden ingesteld volgens de “De thermostaat in bedrijf stellen”. Let erop dat een OCD3 die is veranderd in een OCC3 (zie 4. Geavanceerde instellingen en uitlezing. Type kiezen) weer terug zal gaan naar een OCD3.

This manual is also suitable for:

Ocd3