SUZ-KA50VA
SUZ-KA60VA
SUZ-KA71VA
MAX. REFRIGERANT PIPING LENGTH
Model
SUZ-KA50VA
SUZ-KA60VA
SUZ-KA71VA
MAX. HEIGHT DIFFERENCE
Indoor
unit
w Max. Height
difference 15m
w Height difference should be within 15m regardless of which unit, indoor or outdoor position is high.
ADDITIONAL REFRIGERANT CHARGE(R410A : g)
Outdoor unit
Model
precharged
SUZ-KA50VA
SUZ-KA60VA
Outdoor unit
Model
precharged
SUZ-KA71VA
Refrigerant piping
Max. length : m
A
30
Refrigerant Piping
Max. length
7m
1,600
0
1,800
0
7m
2,000
0
Piping size O.D : mm
Liquid
Gas
12.7
6.35
15.88
9.52
A
Outdoor unit
Refrigerant piping length (one way)
10m
15m
160
60
160
60
Calculation : Xg=20g/m
Refrigerant piping length (one way)
10m
15m
165
440
Calculation : Xg=55g/mo(Refrigerant piping length(m)-7)
45
20m
25m
260
360
260
360
(Refrigerant piping length (m)–7)
20m
25m
715
990
30m
460
460
30m
1,265