Circuit Operation (Charger Unit) - Panasonic KX-TG4732B Service Manual

Hide thumbs Also See for KX-TG4732B:
Table of Contents

Advertisement

4.7.3.
Charge Circuit
Circuit Operation:
When charging the handset on the Base Unit, the charge current is as follows;
DC+(6.5 V) → F301 → R371 → R372 →CHARGE+(Base) → CHARGE+(Handset) → Q4 → D7→ F1 → BATTERY+... Battery...
BATTERY- → R45 → GND → CHARGE-(Handset)→ CHARGE-(Base) → GND → DC-(GND)
In this way, the BBIC on Handset detects the fact that the battery is charged.
The charge current is controlled by switching Q9 of Handset.
Refer to Fig.101 in Power Supply Circuit/Reset Circuit (P.12).
CHG +
CHG -
4.7.4.
Battery Low/Power Down Detector
Circuit Operation:
"Battery Low" and "Power Down" are detected by BBIC which check the voltage from battery.
The detected voltage is as follows;
• Battery Low
Battery voltage: V(Batt)
The BBIC detects this level and "
• Power Down
Battery voltage: V(Batt)
The BBIC detects this level and power down.
4.7.5.
Speakerphone
The hands-free loudspeaker at SP+ and SP- is used to generate the ring alarm.
4.8.

Circuit Operation (Charger Unit)

Charge control is executed at handset side so that the operation when using charger is also controlled by handset.
Refer to Circuit Operation (Handset) (P.20)
The route for this is as follows: DC+pin of J1(+) → F1 → R1 → CHARGE+pad → Handset → CHARGE-pad → DC-pin of J1(-).
Downloaded from
www.Manualslib.com
R8
R4
47K
GND
R7
100K
2.35 V ± 50 mV
" starts flashing.
2.0 V ± 50 mV
F1
J1
AC Adaptor
manuals search engine
Q2
C27
R2
Q3
Q4
R6
10K
Q9
GND
GND
R1
R2
21
KX-TG4732B/KX-TG4733B/KX-TG4734B/KX-TGA470B
BATT +
BATTERY
2CELL
BATT +
CHG CTRL (32)
CHG DET (34)
D1
TP1
TP2
BBIC
IC1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tg4733bKx-tg4734bKx-tga470b

Table of Contents