OUTLINES AND DIMENSIONS

PLFY-P08NBMU-E2
PLFY-P24NBMU-E2
25/32~1-25/32(20~45)
33-27/32 to 35-13/16(860~910)
Fresh air
6-16/5
intake hole
(160)
For MA-Remote controller
terminal block
Indoor unit/Outdoor unit
Branch duct hole
connecting terminal block
7-3/8
Suspension bolt
(187.5)
M10 or W3/8
(60)
2-3/8
1
2
Suspension bolt
lower edge
M
Air intake
grille
M
Corner pocket
Indoor unit
Ceiling
Grille
Min.19-11/16(500)
Entire
periphery
OCH579
PLFY-P12NBMU-E2
PLFY-P30NBMU-E2
Ceiling hole
25/32 to 1-25/32(20~45)
31-7/8(810)
Suspension bolt pitch
For wiring replacement kit
terminal block
6-5/16
(160)
(840)
33-1/16
Drain pipe
(284)
(377)
connected to VP-25
11-3/16
14-27/32
Ceiling
Grille
23-1/2
(597)
Air intake hole
Drain hole
Drain pump clean hole
and Drain emergency
drainage hole
M
M
Vane motor
(500)
19-11/16
1-27/64
Air outlet hole
3-17/64
37-3/8
(950)
(83)
Min.94-1/2(2400)
from floor
Floor
PLFY-P15NBMU-E2
PLFY-P36NBMU-E2
Detail connecting of branch duct (Both aspects)
3-15/16
(90)
3-17/32
Branch
ø6-7/8(ø175)
duct hole
Burring hole pitch
Detail drawing of fresh air intake hole
(
)
Connected the attached
flexible pipe or socket.
Keep 25/64(10) to 19/32(15)
between unit ceiling
and ceiling slab.
In case of standard grille
Auto vane
(Air outlet)
Note:
1. Please choose the Grille from a standard grille.
2. As for drain pipe, please use VP-25 (O.D. [1-1/4([32) PVC TUBE.)
Drain pump is included.
Max. lifting height is 70-7/18 (850mm) from the ceiling.
3. As for suspension bolt, please use M10 or W3/8. (Procured at local site)
4. Electrical box may be removed for the service purpose.
Make sure to slack the electrical wire little bit for control/power wires connection.
5. The height of the indoor unit is able to be adjusted with the grille attached.
6. For the installation of the optional high efficiency filter or optional multi-functional
casement.
1) Add 5-5/16"(135mm) to the dimensions Wmarked on the figure.
(36)
2) The optional high efficiency filter becomes optional multi-functional casement
and concomitant use.
7. When installing the branch ducts, be sure to insulate adequately.
Otherwise condensation and dripping may occur.
(It becomes the cause of dew drops/water dew.)
8. As for necessary installation/service space, please refer to the left figure.
Service ref.
1
PLFY-P08NBMU-E2
Refrigerant pipe···ø6.35
PLFY-P12NBMU-E2
Flared connection···1/4F
PLFY-P15NBMU-E2
PLFY-P18NBMU-E2
Refrigerant pipe···ø9.52
PLFY-P24NBMU-E2
Flared connection···3/8F
PLFY-P30NBMU-E2
PLFY-P36NBMU-E2
13
PLFY-P18NBMU-E2
Unit: in (mm)
3-15/16
(100)
(100)
3-17/32
(90)
Cut out hole
13-25/32
14-ø1/8(14-ø2.8)
(350)
Burring hole
ø5-29/32(ø150)
Cut out hole
Burring hole
3-ø1/8(3-ø2.8)
Burring hole pitch
ø4-29/32(ø125)
Cut out hole
ø3-15/16(ø100)
Ceiling
In case of Auto grille
In case of wireless remote controller
Emergency operation switch <Cooling>
and Emergency Up/Down switch <Up>
Emergency operation switch <Heating>
and Emergency Up/Down switch <Down>
Receiver
Operation lamp
DEFROST/STAND BY lamp
A
B
C
2
Refrigerant pipe ···ø12.7
Flared connection ···1/2F
9-1/2
10-3/16
3-5/32
(241)
(258)
(80)
Refrigerant pipe ···ø15.88
11-1/16
11-3/4
3-11/32
Flared connection ···5/8F
(281)
(298)
(85)
D
2-29/32
(74)
3-1/32
(77)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents