Selection Of Installation Location; Outdoor Unit - Mitsubishi Electric SRK05CR-S Technical Manual

Table of Contents

Advertisement

Standard accessories
(Installation kit)
Accessories for indoor unit
Installation board
(Attached to the rear of the indoor
unit)
② Wireless remote control
③ Remote control holder
Tapping screws
(for installation board 4dia. by 25mm)
Wood screw
(for remote contorol switch holder 3.5dia.
by 16mm)
⑥ Battery [R03 (AAA, Micro) 1.5V]
Option parts
Sealing plate
Sleeve
Inclination plate
Putty
Drain hose (extention hose)
Piping cover
(for insulation of connection piping)

Selection of installation location

INDOOR UNIT
① Where there is no obstructions to the air flow and where the cooled air can
be evenly distributed.
② A solid place where the unit or the wall will not vibrate.
③ A place where there will be enough space for servicing. (Where space
mentioned right can be secured)
④ Where wiring and the piping work will be easy to conduct.
⑤ The place where receiving part is not exposed to the direct rays of the sun
or the strong rays of the street lighting.
⑥ A place where it can be easily drained.
⑦ A place separated at least 1m away from the television or the radio.
(To prevent interfence to images and sounds.)
⑧ A place that home appliance and household goods, etc. aren't below unit.

OUTDOOR UNIT

① A place where good air circulation can be obtained and where rain, snow
or sunshine will not directly strike the unit.
② A place where discharged hot air or unit's operating sound will not be a
nuisance to the neighborhood.
③ A place where servicing space can be secured.
④ A place where vibration will not be enlarged.
*Avoid installing in the following places.
place near the bedroom and the like, so that the operation noise will
cause no trouble.
A place where there is possibility of flammable gas leakage.
exposed to strong wind.
a salt-laden atmosphere or a place where the generation of oil mist,
vapor or fume is expected.
⑤ Blowing out port and suction port on the back side of the unit can be
installed at a distance of 10cm from walls.
(
case the barrier is 1.2m or above in height, or is overhead, the
sufficient space between the unit and wall shall be secured.
⑥ When the unit is installed, the space of the following dimension and above
shall be secured.
RMA012A080_091-093_EN.indb 28
Necessary tools for the installation work
Q'ty
1
Plus headed driver (Phillips screwdriver)
2
Knife
1
3
Saw
4
Tape measure
1
5
Hammer
1
6
Spanner wrench
5
7
Torque wrench
8
Hole core drill (65mm in diameter)
2
9
Wrench key (Hexagon) [4m/m]
10
Vacuum pump
2
Vacuum pump adapter
Q'ty
11
(Anti-reverse
type)
1
12
Gauge manifold
1
13
Change hose
1
1
14
Flaring tool set
1
Gas leak detec-
15
tor
1
Gauge for projection adjustment (Used when
16
is made by using conventional
17
Pipe bender
– 28 –

-
-
(
)
14.0 ~ 82.0N · m
(1.4 ~ 8.2kgf · m)
(
)
Designed
for R410A
(
)
Designed
for R410A
(
)
Designed
for R410A
(
)
Designed
for R410A
(
)
Designed
for R410A
tool)
10 cm
Left
side
5 cm
Air intake
10 cm
Air
intake
Air outlet
Note (1)
the wall is higher than 1.2 m or a
ceiling is present, distances larger than
indicated in the above table must be
provided.
)
'15 • SRK-T-171
Right
side
10 cm
No obstacles
(Service space
for electrical
parts)
05/11/2014 11:50:41