Mitsubishi Electric SRK05CR-S Technical Manual page 13

Table of Contents

Advertisement

Item
Cooling capacity (1)
Power source
Power
consumption
Running
current
Operation
data
Inrush current
COP
Noise
Cooling
level
Exterior dimensions (Height x Width x Depth)
Exterior appearance
(Munsell color)
Net weight
Compressor type & Q'ty
Motor (Starting method)
Refrigerant oil
Refrigerant
Refrigerant (4)
equipment
Heat exchanger
Refrigerant control
Device control
Fan type & Q'ty
Motor
Air handling
Air flow
equipment
Fresh air intake
Air filter, Quality / Quantity
Shock & vibration absorber
Operation switch
Operation
Room temperature control
control
Operation display
Safety devices
Refrigerant piping size (O.D)
Connecting method
Attached length of piping
Installation
data
Insulation for piping
Refrigerant line (one way) length
Vertical height difference between
outdoor unit and indoor unit
Drain hose
Power cable
Recommended breaker size
Connection wiring
Accessories (included)
Option parts
Note (1) The data are measured at the following conditions.
Item
Operation
Cooling
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 5m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is 5m to 15m, additional refrigerant is 10g per each 1m longer than 5m.
Model
W
Cooling
kW
Cooling
A
Cooling
Sound level
dB(A)
Power level
dB
mm
kg
kW
kg
W
3
Cooling
m
/min
mm
m
m
A
Size x Core number
Connecting method
Indoor air temperature
DB
WB
27˚C
19˚C
Indoor unit SRK09CR-S4
1 Phase, 220-240V, 50Hz
43
57
262 x 615 x 210
Fine snow
(8.0Y 9.3/0.1) near equivalent
6
0.30 (POE [RB68A] or PVE [FVC68D])
R410A 0.52 ( Pre-charged up to the piping length of 5m )
Louver fins & inner grooved tubing
Microcomputer control
Cross flow fan x 1
17
9
Not possible
Polypropylene net (washable) x 1
Wireless remote control
Microcomputer thermostat
RUN : Green, TIMER : Yellow
Compressor overheat protection, Overcurrent protection,
Frost protection, Serial signal error protection, Indoor Fan motor error protection,
Cooling overload protection
Liquid line: φ6.35 (1/4")
Liquid line : 0.46
Gas line : 0.40
Necessary (Both sides), independent
Max.5 (Outdoor unit is higher)
Max.5 (Outdoor unit is lower)
Connectable (VP 16)
2
1.5mm
x 3 cores (Including earth cable)
Terminal block (Screw fixing type)
Outdoor air temperature
DB
WB
35˚C
24˚C
ISO-T1, JIS C 9612

-
-
'15 • SRK-T-171
SRK09CR-S4
Outdoor unit SRC09CR-S4
2500
0.893
4.1 / 3.9
15
2.80
50
61
435 x 645 (+50) x 275
Stucco white
(4.2Y 7.5/1.1) near equivalent
24.5
GKS102PAB (Rotary type) x 1
PSC
Louver fins & inner grooved tubing
Capillary tubes
Propeller fan x 1
22
23
Cushion rubber (for compressor)
Gas line: φ9.52 (3/8")
Flare connecting
Max. 15
10
Mounting kit
The pipe length is 5m.
Standards

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk05crp-sSrk12cr-sSrk09cr-sSrk09crp-sSrk09crr-s