TECHNICAL DATA

DIMENSIONS
Height to hotplate
Space for fixing at hotplate level
Space for fixing above hotplate level
Minimum space above hotplate
Weight of appliance
Minimum distance from rear wall
CONNECTIONS
Gas
Electric
IGNITION
Spark generator
Battery
GRILL
Heat Input
Injector Marking
HOTPLATE
Heat Input
Injector Marking
MAIN OVEN
Heat Input
Injector Marking
Flame Supervision Device
Thermostat
Marking
GENERAL
Ignition
Spark Gap
S H E R A T O N
Height
900mm (nominal)
2mm minimum clearance
See important note'Location of Appliance' page 34.
787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).
64.5kg.
5mm (spacer given by pressed spacer on vent panel).
Rear left hand side of appliance at hotplate level.
Rc½ (½" B.S.P. female).
None
APCO 6BG 6893
1.5 Volt AA size
Natural Gas
3.3kW (11263 Btu/h)
138
R.H.F.
1.0kW
(3412 Btu/h)
(6824 Btu/h
079
Natural Gas
2.4kW (8189Btu/h)
108
Diamond'H' GSD 100/28
Diamond'H' 1100-93/B2
69
H. T. Spark
3-4mm
32
Width
600mm (nominal)
Natural Gas
R.H.R.
L.H.R.
2.0kW
2.0kW
(6824 Btu/h)
104
104
Deptth
600mm
(to front of
door panel)
L.H.F
2.8kW
(9554 Btu/h)
130