Important
Safety Instructions
24. Flame size should be adjusted so it does not extend
IMPORTANT
SAFETY
NOTICE
beyond the edge of the cookware. This instruction is
AND
WARNING
based on safety consideration.
25. This appliance has been tested for safe performance
The California Safe Drinking Water andToxic Enforcement
Act of 1986 (Proposition 65) requires the Governor of Call-
using conventional cookware. Do not use any devices or
accessories that are not specifically recommended in this
fornia to publish a list of substances known to the State of
manual. Do not use eyelid covers for the surface burners
California to cause cancer or reproductive harm, and requires
or elements or stovetop grills. The use of devices or
businesses to warn customers of potential exposures to such
accessories that are not expressly recommended in this
substances.
manual can create serious safety hazards, result in perfor-
mance problems and reduce the life of the components of
Users of this appliance are hereby warned that the burning of
the appliance,
gas can result in low-level exposure to some of the listed
substances, including benzene, formaldehyde and soot, due
26. Before servicing shut off electrical power supply to
primarily to the incomplete combustion of natural gas or
appliance,
liquid petroleum (LP) fuels. Properly adjusted burners will
minimize incomplete combustion. Exposure to these sub-
27. Keep vent area unobstructed when in use.
stances can be minimized by properly venting the cooktop to
the outdoors.
28. Do not operate with damaged grill element or any prod-
uct malfunction until proper repair has been made.
SAVE THESE INSTRUCTIONS
Ducting
4
Ducting Considerations
, Recommended Jenn-Air wall cap MUST be used. Make
sure damper moves freely when ventilation system is
Jenn-Air's ventilation system is designed to capture both
operating.
cooking fumes and smoke from the cooktop surface. If the
• There should be a minimum clearance of 6" for cooktop
system does not, these are some ducting installation situations
installed near a side wall.
to check:
If there is not an obvious improper installation, there may be
• 6" diameter round or 3 74"x 10"rectangular ducting should
a concealed problem such as a pinched joint, obstruction in
be used for duct lengths 10'-60'. Note: 5" diameter round
the pipe, etc. Installation is the responsibility of the installer
ducting must be used for venting straight out the back of
and questions should be addressed first by the installer. The
the cooktop and directly through the wall for 10' or less.
installer should very carefully check the ducting installation
• No more than three 90 ° elbows should be used. Distance
instructions.
between elbows should be at least 18".