GlasCraft Equipment
Air Hose is 1/4" in. NPS
JIC Fittings DO NOT require the use of PTFE tape.
Once the fittings are attached and tight, refer to system
manuals for start-up instructions.
*AIR
POLY
The P2 Elite gun attaches the same way if equipped
with the optional horizontal set-up.
* Fitting GC2394 is an unattached part that may need to be
connected to the air hose first, and then connected to the
gun depending on the air hose fitting.
Installing P2 Elite on Other Equipment
Section 1 - Installation: Equipment Assembly
ISO
WARNING
Do not place any part of the body in the path of the material
spray.
Do not point the gun at or near other personnel.
Do not look into the mixing chamber orifice at any time.
Because of the hazardous materials used in this equip-
ment, it is recommended that the operator use an air mask,
goggles, protective clothing, and other safety equipment
as prescribed by current regulations, recommendations of
the chemical suppliers, and the laws in the area where the
equipment is being used.
If original equipment does not require the use of an un-
heated whip hose or isolation hose, the P2 can be directly
installed on to the material hose.
Remove the fittings from the original gun.
1.
Remove swivel fittings from ball valves. Ball valves
2.
are 1/8 in. NPT female. Remove swivel fitting from
air slide valve. The air slide valve is a ¼ in. NPSM.
Install the original fittings into ball valves.
3.
It is recommended to use a non-permanent thread
lock on the 1/8 in. NPT threads to assist as a sealant
and keep the fittings from twisting with gun move-
ment.
4.
Install the gun on the original Hoses.
WARNING
Relieve ALL system fluid and air pressures according to
manufacturer's instructions.
10