FCB Pinnacle 2 and 4 Flavor Installation Manual

INSTALLATION INSTRUCTIONS

I
R
NSTALLATION
EQUIREMENTS
Requirements Summary
Environment
Temperature
CO
2
Syrup
Water
Electrical
60 Hz Unit
50 Hz Unit

Electrical Requirements

Refer to the nameplate to determine the power requirements before connecting electrical power to the unit. All of
the power cords shall comply with safety requirements outlined in the EC Standards (EN60335-1 1 Clause 24.1) in
countries where CE compliance is required. All cords must be HD 21 or HD 22.
Voltage across contactor terminals L1 and L2, with compressor running, must be within voltage limits described in
the Requirement Summary.
!
DANGER:
To avoid possible serious injury or death the ELCB (earth leakage circuit breaker) must be installed in the electrical
circuit of all units.
!
WARNING:
To avoid possible electrical shock make sure the unit is properly grounded by connecting the earth ground cable, in
the power cord, to any connection in the machine marked with a ground symbol.
!
CAUTION:
The wiring must be properly grounded and connected through a disconnect switch (slow–blow fuse or equivalent
HVAC/R circuit breaker - 20 amp for the 2 Flavor model and 40 amp for the 4 Flavor model) for 60Hz units. Refer to
the local and national wiring codes for the 50Hz unit. All wiring must conform to national and local codes.
Line Voltage
The recommended line voltages for the Pinnacle unit are as follows:
The unit has a low voltage cut out at 180 VAC and a high voltage cut out at 260 VAC.
Below 180 V
180 to 190 VAC
191 to 208 VAC
209 to 240 VAC
241 to 253 VAC
254 to 272 VAC
Above 272 VAC
Publication Number: 560007295INS
Indoor installation only
40 to 90°F ambient temperature
60 psi minimum at unit
60 psi minimum at pressure switch,.35 ounces per sec. (.17 gpm) at unit
25 psi minimum (flowing), 3.5 ounces per sec./100 gallon per hour minimum (per 2
barrels). Minimum 1/2" ID water inlet recommended
208-230 volts, 20 amp, 60 Hz (2 Flavor)
208-230 volts, 40 amp, 60 Hz (4 Flavor)
230 volts, 15 amp, 50 Hz (2 Flavor)
Voltage
Corrective Action
DO NOT connect unit.
Boost voltage by +32 V.
Boost voltage by +16 V.
Use line voltage.
Reduce voltage by -16 V.
Reduce voltage by -32 V.
DO NOT connect unit.