Sharp ER-A57R1 Service Manual page 42

Table of Contents

Advertisement

2. IRC test 2 (FLAG send)
1 Getting started
Get started with JOB #601.
SRV mode: 601
TL
2 Content
FLAG (7EH) is continuously transmitted. The following display is
given during the execution. (Execution of diag command 3)
∆ΟΤ− ∆ΙΣΠ ΛΑΨ :
I R C
3 Test check content
The FLAG to be transmitted is checked by the hardware.
4 Cancellation
To cancel this test, perform the SRV reset.
3. IRC test 3 (DATA send)
1 Getting started
Get started with JOB #602.
SRV mode: 602
TL
2 Test content
Data of 256 byte in 00 - 0FFH are formed as one packet, and the
packets are continuously transmitted in the packet interval of 12.8
msec at 480 kbps. (Execution of diag command 4)
∆ΟΤ− ∆ΙΣΠ ΛΑΨ :
I R C
3 Check content
The data to be transmitted are checked by the hardware.
4 Cancellation
To cancel this test, perform the SRV reset.
F L A G
C K
S R V.
601
D A T A
C K
S R V.
602
4. IRC test 4, 5 (Data transmission test)
This test is intended to perform data transmission test in an actually
configured system. The system to be tested is composed of one set
of master machine (set by JOB #604) and max. 15 sets of slave
machines (set by JOB #603).
Note for starting the test:
When testing a set in which the IRC setting has been already
made, be sure to cancel the inline setting in the following proce-
dure before performing this test.
To cancel the inline setting:
SRV mode: 902
When testing an already configured system, cancel the inline set-
ting of the set which are not to be tested in the above procedure or
disconnect their signal lines. (Disconnect the inner cable and the
joint connector.) If the test is executed without cancelling the inline
setting of a set which is not to be tested, the data in the set may be
destroyed.
Cancel the inline setting of all the sets in the system before per-
forming the transmission test (JOB #603, JOB #604) setting. Per-
form the satellite machine setting (JOB #603) before performing
the master machine setting (JOB #604).
Note for terminating the test:
After terminating the test of all the sets used in the test (by the
program resetting), perform setting of each set.
For the set whose inline setting was cancelled before the test
because its IRC setting had been made, perform the inline setting
in the following procedure. This test will not affect the other set-
tings.
To set the inline setting YES:
SRV mode: 902
1 Satellite machine setting (JOB #603)
Starting
SRV mode: 603
∆ΟΤ− ∆ΙΣΠ ΛΑΨ :
S L
Test terminal No. input and test start
XXX
TL
(XXX: 000 - 254)
XXX: Test slave machine terminal No.
∆ΟΤ− ∆ΙΣΠ ΛΑΨ :
S L
3 ™ 4
0XXX
X
XXX: Set as required.
1XXX
X
TL
:
0 0 0
: X X X
TL
TL
S R V.
S R V.

Hide quick links: