E14CL4b Transducer
16-01277-EN-02
For Professional Users Only
September 2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E14CL4b and is the answer not in the manual?

Questions and answers

Summary of Contents for bk ultrasound E14CL4b

  • Page 1 User Guide E14CL4b Transducer 16-01277-EN-02 For Professional Users Only September 2015...
  • Page 2 If you have comments about the user documentation, please write to us at the email address above. We would like to hear from you. E14CL4b = Ref. Type 9048 © 2015 BK Medical Information in this document may be subject to change without notice.
  • Page 3: Table Of Contents

    Endorectal Imaging with E14CL4b........9...
  • Page 5: Introduction

    Introduction This is the user guide for the E14CL4b transducer, and it must be used together with the Care and Cleaning user guide which contains important safety information. Caution Rx-c1 Federal law in North America restricts this device to sale to, or on the order of, a Physicians physician.
  • Page 6: General Information

    Sagittal Plane INSERT scanning PLANE IMAGE Transverse Plane Figure 2. Imaging plane for E14CL4b. General Information Product specifications, acoustic output data and data about EMC (electromagnetic compatibility) for this transducer can be found in the Product Data Sheet and the Technical Data (BZ2100) that accompany this user guide.
  • Page 7: Reprocessing

    When connected, the transducer complies with Type BF requirements of EN60601-1 (IEC 60601-1). Changing Frequency The multifrequency imaging (MFI) control enables you to select the imaging frequency. See the applicable system user guide for instructions. The selected frequency is displayed on the monitor. E14CL4b User Guide (16-01277-EN-02)
  • Page 8: Using A Transducer Cover

    Press the button for more than one second to make a copy of the image. Each time the button is pressed, a “beep” is emitted. Changing Orientation To change the orientation of the image on the monitor, refer to the applicable system user guide for instructions. September 2015 E14CL4b User Guide (16-01277-EN-02)
  • Page 9: Endorectal Imaging With E14Cl4B

    The width of the image area can be adjusted using the Width key on the scanner’s control panel. See the applicable system user guide for instructions. With the Expanded Sector feature and E14CL4b, you can increase the transverse sector angle from a default width of 140° to 180°. And, you can increase the default sagittal view of 65mm to a trapezoidal view, which provides an additional 15°on each side.
  • Page 10 No force should be used when attaching the puncture attachment to the transducer. Figure 5. E14CL4b with puncture attachment UA1232. All parts of the puncture attachment can be autoclaved or disinfected by immersion in a suitable solution.
  • Page 11: Performing Puncture And Biopsy

    To remove the puncture line from the scan image, refer to the applicable system user guide for instructions. WARNING P-w5 Avoid unnecessary tissue damage. When performing a biopsy, always make sure that the needle is fully drawn back inside the needle guide before moving the transducer. E14CL4b User Guide (16-01277-EN-02)
  • Page 12: Prostate Volume Determination

    Please consult the appropriate stepper documentation for instructions on Source Implantation, including Preplanning, Needle Loading and Implantation. E14CL4b should be prepared for transrectal imaging and biopsy as described earlier in this guide, and mounted and ’’locked’’ in the stepping unit.
  • Page 13: Cleaning After Puncture And Biopsy

    WARNING D-w1 For contaminated disposals such as transducer covers or needle guides, follow disposal control policies established for your office, department, or hospital. E14CL4b User Guide (16-01277-EN-02)
  • Page 14 September 2015 E14CL4b User Guide (16-01277-EN-02)