Remote controller-less setting
To set up the external static pressure, use the DIP switch on the circuit board of the wireless reception part.
For details, refer to the instruction manual of the wireless remote controller kit. Alternatively, use the switch on the
indoor micro computer circuit board as shown in the following figure and table.
* Once switched, the settings "0001", "0003", and "0006" can be changed, but to reset to "0000", you need to set
the switch to the normal (default) position and use a separately-sold wired remote controller to overwrite the data
with "0000".
SW501-2
SW501-1
MCU(IC501)
37-EN
SW501-1
OFF
ON
OFF
SW501-2
OFF
OFF
ON
0000
SET DATA
(Factory
0001
0003
default)
To restore the factory defaults
To return the DIP switch settings to the factory defaults, set
SW501-1 and SW501-2 to OFF, connect a separately sold wired
remote controller, and then set the data of CODE No. [5d] to "0000".
– 19 –
Filter sign setting
According to the installation condition, the filter sign
term (Notification of filter cleaning) can be changed.
Follow to the basic operation procedure
1
2
3
4
5
(
For the CODE No. in Procedure
For the [SET DATA] in Procedure
DATA of filter sign term from the following table.
ON
SET DATA
ON
0000
0001
0006
0002
0003
0004
To secure better effect of
heating
When it is difficult to obtain satisfactory heating due to
installation place of the indoor unit or structure of the
room, the detection temperature of heating can be
raised. Also use a circulator or other device to circulate
heat air near the ceiling.
Follow to the basic operation procedure
1
2
3
4
5
(
For the CODE No. in Procedure
For the SET DATA in Procedure
DATA of shift value of detection temperature to be
set up from the following table.
SET DATA
Detection temperature shift value
0000
0001
0002
0003
0004
0005
0006
Power saving mode
Performing settings of the power saving
mode
6
).
3
, specify [01].
4
, select the SET
Filter sign term
None
150 H
5
2500 H
(Factory default)
1
Push
5000 H
more when the air conditioner is not
10000 H
working.
, symbol flashes.
2
Push
select an indoor unit to be set.
Each time the button is pushed, UNIT No.
change as follows:
UNIT No.
1-1
6
).
3
, specify [06].
The fan of the selected unit runs.
4
, select the SET
3
Push TIME
setting of power level.
Each push of the button changes the power
level by 1% within the range from 100% to 50%.
No shift
The factory default is 75%
+1 °C
+2 °C
(Factory default)
+3 °C
+4 °C
+5 °C
+6 °C
4
Push
button.
5
Push
button to complete the setting.
1
4 3
2
button for at least 4 seconds or
(left side of the button) to
UNIT No.
UNIT No.
1-2
1-3
UNIT No.
1-4
buttons, to adjust the
Setting of power level in
power saving mode
38-EN