12.14.2.5
Sunlight Sensor Check Mode
•
To enable sunlight sensor check mode, during unit is OFF (power standby):
•
Operation details
The sunlight sensor check mode will be operated for 5 minutes.
o
During check mode, the ON and OFF timer will be memorized but it operation be ignored.
o
During check mode, if the sunlight sensor check code is retransmitted, the 5 minutes counter will be reset.
o
During check mode, if sunlight sensor detected the sunlight intensity value above minimum level, the
o
ECONAVI indicator turns ON. Else if sunlight sensor detected sunlight intensity value below minimum level,
the ECONAVI indicator is OFF.
•
To disable sunlight sensor check mode
After check mode is ended (5 minutes counter elapsed), press AUTO OFF/ON button at indoor unit.
o
If the sunlight sensor detected sunlight intensity is at abnormal range, the check mode will be ended.
o
Please check for error code.
12.14.2.6
Sunlight Sensor Abnormality
•
Abnormality detection:
When ECONAVI is ON, if the sunlight intensity value below minimum level continuously for 24 hours, the
o
sunlight sensor disconnection error counter will increase by 1 time. If the ECONAVI is OFF, the 24 hours
timer will be reset, but the sunlight sensor disconnection error counter will not be reset.
•
Error Code judgment
When sunlight sensor disconnection error counter reached 15 times. H70 occurred.
o
No TIMER indicator or ECONAVI indicator blink.
o
•
When error code happened, the unit is able to operate without sunlight sensor.
Remote control normal mode
Press continously for 15s
SET
SET
Transmit ECO demo code
and after 2 seconds return to normal
mode.
SET
Transmit check code
and after 2 seconds return to normal
mode.
SET
Transmit sunlight sensor check code
and after 2 seconds return to normal
mode.
92